Literature DB >> 19038879

Diagnostic performance of coronary angiography by 64-row CT.

Julie M Miller1, Carlos E Rochitte, Marc Dewey, Armin Arbab-Zadeh, Hiroyuki Niinuma, Ilan Gottlieb, Narinder Paul, Melvin E Clouse, Edward P Shapiro, John Hoe, Albert C Lardo, David E Bush, Albert de Roos, Christopher Cox, Jeffery Brinker, João A C Lima.   

Abstract

BACKGROUND: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established.
METHODS: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index.
RESULTS: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography.
CONCLUSIONS: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.) 2008 Massachusetts Medical Society

Entities:  

Mesh:

Year:  2008        PMID: 19038879     DOI: 10.1056/NEJMoa0806576

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  484 in total

1.  Ischemic heart disease associated with bortezomib treatment combined with dexamethasone in a patient with multiple myeloma.

Authors:  Hiroyuki Takamatsu; Takeshi Yamashita; Takeharu Kotani; Aiko Sawazaki; Hirokazu Okumura; Shinji Nakao
Journal:  Int J Hematol       Date:  2010-05-11       Impact factor: 2.490

2.  Relationship of left ventricular mass to coronary atherosclerosis and myocardial ischaemia: the CORE320 multicenter study.

Authors:  Satoru Kishi; Tiago A Magalhaes; Richard T George; Marc Dewey; Roger J Laham; Hiroyuki Niinuma; Lisa Aronson Friedman; Christopher Cox; Yutaka Tanami; Joanne D Schuijf; Andrea L Vavere; Kakuya Kitagawa; Marcus Y Chen; Cesar H Nomura; Jeffrey A Brinker; Frank J Rybicki; Marcelo F Di Carli; Armin Arbab-Zadeh; Joao A C Lima
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-11-02       Impact factor: 6.875

3.  Assessment of myocardial infarction by CT angiography and cardiovascular MRI in patients with cocaine-associated chest pain: a pilot study.

Authors:  K Paraschin; A Guerra De Andrade; J Rodrigues Parga
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

4.  Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic study.

Authors:  Andrea L Vavere; Gregory G Simon; Richard T George; Carlos E Rochitte; Andrew E Arai; Julie M Miller; Marcello Di Carli; Armin Arbab-Zadeh; Armin A Zadeh; Marc Dewey; Hiroyuki Niinuma; Roger Laham; Frank J Rybicki; Joanne D Schuijf; Narinder Paul; John Hoe; Sachio Kuribyashi; Hajime Sakuma; Cesar Nomura; Tan Swee Yaw; Klaus F Kofoed; Kunihiro Yoshioka; Melvin E Clouse; Jeffrey Brinker; Christopher Cox; Joao A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-11-12

5.  Automatic vs semi-automatic global cardiac function assessment using 64-row CT.

Authors:  J Greupner; E Zimmermann; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

Review 6.  Stress CT perfusion: coupling coronary anatomy with physiology.

Authors:  Edward A Hulten; Marcio Sommer Bittencourt; Brian Ghoshhajra; Ron Blankstein
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

7.  Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM).

Authors:  E di Cesare; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; L Natale; A Romagnoli; V Russo; F Sardanelli; F Cademartiri
Journal:  Radiol Med       Date:  2012-04-01       Impact factor: 3.469

Review 8.  Non-invasive functional assessment using computed tomography: when will they be ready for clinical use?

Authors:  Yeonyee E Yoon; Bon-Kwon Koo
Journal:  Cardiovasc Diagn Ther       Date:  2012-06

9.  An Human-Computer Interactive Augmented Reality System for Coronary Artery Diagnosis Planning and Training.

Authors:  Qiming Li; Chen Huang; Shengqing Lv; Zeyu Li; Yimin Chen; Lizhuang Ma
Journal:  J Med Syst       Date:  2017-09-02       Impact factor: 4.460

10.  Development of new risk score for pre-test probability of obstructive coronary artery disease based on coronary CT angiography.

Authors:  Shinichiro Fujimoto; Takeshi Kondo; Hideya Yamamoto; Naoyuki Yokoyama; Yasuhiro Tarutani; Kazuhisa Takamura; Yoji Urabe; Kumiko Konno; Yuji Nishizaki; Tomohiro Shinozaki; Yasuki Kihara; Hiroyuki Daida; Takaaki Isshiki; Shinichi Takase
Journal:  Heart Vessels       Date:  2014-04-27       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.