Literature DB >> 17715102

Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

David Matt1, Hans Scheffel, Sebastian Leschka, Thomas G Flohr, Borut Marincek, Philipp A Kaufmann, Hatem Alkadhi.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS: Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment.
RESULTS: Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution.
CONCLUSION: The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.

Entities:  

Mesh:

Year:  2007        PMID: 17715102     DOI: 10.2214/AJR.07.2078

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  49 in total

1.  Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience.

Authors:  Zhaoping Cheng; Ximing Wang; Yanhua Duan; Lebin Wu; Dawei Wu; Baoting Chao; Cheng Liu; Zhuodong Xu; Hongxin Li; Fei Liang; Jian Xu; Jiuhong Chen
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

2.  320-detector CT coronary angiography with prospective and retrospective electrocardiogram gating in a single heartbeat: comparison of image quality and radiation dose.

Authors:  J Qin; L-Y Liu; Y Fang; J-M Zhu; Z Wu; K-S Zhu; J-S Zhang; H Shan
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

3.  Assessment of global function of left ventricle with dual-source CT in patients with severe arrhythmia: a comparison with the use of two-dimensional transthoracic echocardiography.

Authors:  Song Soo Kim; Sung Min Ko; Meong Gun Song; Joon Suk Kim
Journal:  Int J Cardiovasc Imaging       Date:  2010-08-27       Impact factor: 2.357

Review 4.  Dual-source cardiac computed tomography: image quality and dose considerations.

Authors:  Stephan Achenbach; Katharina Anders; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-02-26       Impact factor: 5.315

5.  Dual-source computed tomographic coronary angiography: image quality and stenosis diagnosis in patients with high heart rates.

Authors:  Minwen Zheng; Jiayi Li; Jian Xu; Kang Chen; Hongliang Zhao; Yi Huan
Journal:  Tex Heart Inst J       Date:  2009

6.  Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography.

Authors:  H Seifarth; M Puesken; S Wienbeck; D Maintz; R Fischbach; W Heindel; K-U Juergens
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

Review 7.  Recent developments in wide-detector cardiac computed tomography.

Authors:  Sang Il Choi; Richard T George; Karl H Schuleri; Eun Ju Chun; Joao A C Lima; Albert C Lardo
Journal:  Int J Cardiovasc Imaging       Date:  2009-03-03       Impact factor: 2.357

8.  Aortic valves stenosis and regurgitation: assessment with dual source computed tomography.

Authors:  Xiaofei Li; Lijun Tang; Lei Zhou; Yuqing Duan; Sheng Yanhui; Rong Yang; Yanhu Wu; Xiangqing Kong
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-07       Impact factor: 2.357

9.  Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease.

Authors:  Moez Ben Saad; Adela Rohnean; Anne Sigal-Cinqualbre; Ghazal Adler; Jean-Francois Paul
Journal:  Pediatr Radiol       Date:  2009-03-25

10.  Image reconstruction and image quality evaluation for a dual source CT scanner.

Authors:  T G Flohr; H Bruder; K Stierstorfer; M Petersilka; B Schmidt; C H McCollough
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.