Literature DB >> 21679894

High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy.

Michael Scharf1, Ricarda Bink, Matthias S May, Christian Hentschke, Stephan Achenbach, Michael Uder, Michael M Lell.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the mean heart rate and heart rate variability (HRV) required for diagnostic imaging of the coronary arteries simultaneously with thoracic computed tomography for noncardiac purposes, applying a high-pitch spiral image acquisition protocol for computed tomography angiography (CTA) using a dual-source system.
BACKGROUND: For the primary prevention of coronary heart disease, screening methods to identify currently asymptomatic people who are at high risk for developing coronary heart disease are essential. Coronary CTA can rule out coronary artery stenoses with high negative predictive value.
METHODS: High-pitch thoracic computed tomography was performed in 111 consecutive patients (mean age 60.2 ± 11.5 years; range 37 to 81 years) using a dual-source system (2 × 128 0.6-mm sections, 38.4-mm collimation width, 0.28-s rotation time). Data acquisition was prospectively electrocardiographically triggered at 60% of the R-R interval using a pitch of 3.2. Image quality was evaluated using a 3-point scale (1=excellent, 2=moderate, 3=poor).
RESULTS: Close interobserver agreement for image quality scores of 1,998 evaluated coronary segments was found (κ=0.93). Image quality was of diagnostic value in 828 of 1,739 segments (47.6%). In 29 of 111 patients (26%), diagnostic image quality was observed for all segments. Average heart rate and HRV were significantly (p<0.001) higher in patients with at least 1 nondiagnostic coronary segment compared with those without. All patients with mean heart rates <64 beats/min and HRV <13 beats/min had diagnostic image quality in all coronary segments. Effective radiation dose for thoracic CTA was 1.9 ± 0.66 mSv. The mean scan time was 0.9 ± 0.1 s.
CONCLUSIONS: Simultaneous evaluation of coronary arteries in high-pitch dual-source CTA of the thorax for noncardiac purposes is consistently diagnostic in patients with low heart rates and HRV, whereas most patients not receiving beta-blockers had at least 1 segment that was not diagnostic because of heart rate and HRV. Beta blockers are recommended if there are no contraindications and coronary interpretation is anticipated.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21679894     DOI: 10.1016/j.jcmg.2011.02.014

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  9 in total

1.  Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction.

Authors:  Heon Lee; Jeong A Kim; Ji Sung Lee; Jon Suh; Sang Hyun Paik; Jai Soung Park
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-20       Impact factor: 2.357

2.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

Authors:  Sonja Gordic; Daniela B Husarik; Lotus Desbiolles; Sebastian Leschka; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-11       Impact factor: 2.357

3.  Virtual clinical trial for quantifying the effects of beam collimation and pitch on image quality in computed tomography.

Authors:  Ehsan Abadi; William P Segars; Brian Harrawood; Shobhit Sharma; Anuj Kapadia; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-06-01

4.  Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom.

Authors:  Martin Beeres; Ralf W Bauer; Josef M Kerl; Thomas J Vogl; Clara Lee
Journal:  J Clin Imaging Sci       Date:  2015-01-30

5.  Recent Update on Radiation Dose Assessment for the State-of-the-Art Coronary Computed Tomography Angiography Protocols.

Authors:  Sock Keow Tan; Chai Hong Yeong; Kwan Hoong Ng; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  PLoS One       Date:  2016-08-23       Impact factor: 3.240

6.  High-pitch, 120 kVp/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers.

Authors:  Hyun Kyung Lim; Hong Il Ha; Hye Jeon Hwang; Kwanseop Lee
Journal:  PLoS One       Date:  2019-01-24       Impact factor: 3.240

7.  Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced.

Authors:  Katherine Kaproth-Joslin; Susan Hobbs; Prabhakar Rajiah; Apeksha Chaturvedi; Abhishek Chaturvedi
Journal:  J Clin Imaging Sci       Date:  2022-07-29

8.  Influence of trigger type, tube voltage and heart rate on calcified plaque imaging in dual source cardiac computed tomography: phantom study.

Authors:  Tobias Penzkofer; Eva Donandt; Peter Isfort; Thomas Allmendinger; Christiane K Kuhl; Andreas H Mahnken; Philipp Bruners
Journal:  BMC Med Imaging       Date:  2014-09-01       Impact factor: 1.930

9.  Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-10-18       Impact factor: 3.500

  9 in total