Literature DB >> 17061071

Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients.

Damien Delhaye1, Martine Remy-Jardin, Céline Rozel, Catherine Dusson, Alain Wurtz, Valérie Delannoy-Deken, Alain Duhamel, Jacques Remy.   

Abstract

The purpose of this study was to evaluate the clinical feasibility of coronary artery imaging during routine preoperative 64-slice MDCT scans of the chest. Ninety-nine consecutive patients in sinus rhythm underwent a biphasic multidetector-row spiral CT examination of the chest without the administration of beta-blockers, including an ECG-gated acquisition over the cardiac cavities, followed by a non-gated examination of the upper third of the thorax. Data were reconstructed to evaluate coronary arteries and to obtain presurgical staging of the underlying disease. The percentage of assessable segments ranged from 65.4% (972/1,485) when considering all coronary artery segments to 88% (613/693) for the proximal and mid segments, reaching 98% (387/396) for proximal coronary artery segments. The 387 interpretable proximal segments included 97 (97%) LM, 99 (100%) LAD, 96 (97%) LCX and 95 (96%) RCA with a mean attenuation of 280.70+/-52.93 HU. The mean percentage of assessable segments was significantly higher in patients with a heart rate <or=80 bpm (n=48) than in patients with a heart rate greater than 80 bpm (n=35) (80+/-11% vs. 72+/-13%; P=0.0008). Diagnostic image quality was achieved in all patients for preoperative staging of the underlying disorder. The mean estimated effective dose was 12.06+/-3.25 mSv for ECG-gated scans and 13.88+/-3.49 mSv for complete chest examinations. Proximal and mid-coronary artery segments can be adequately evaluated during presurgical CT examinations of the chest obtained with 64-slice MDCT without the administration of beta-blockers.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17061071     DOI: 10.1007/s00330-006-0423-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

1.  Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Authors:  Xavier L Hamoir; Thomas Flohr; Vincent Hamoir; Laurent Labaki; Jean-Yves Tricquet; Alain Duhamel; Jacques Kirsch
Journal:  Eur Radiol       Date:  2004-11-24       Impact factor: 5.315

Review 2.  Performance evaluation of a 64-slice CT system with z-flying focal spot.

Authors:  T Flohr; K Stierstorfer; R Raupach; S Ulzheimer; H Bruder
Journal:  Rofo       Date:  2004-12

3.  Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Authors:  Emmanuel Coche; Alain Vlassenbroek; Véronique Roelants; William D'Hoore; Franck Verschuren; Louis Goncette; Baudouin Maldague
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

Review 4.  Basics of cardiac MDCT: techniques and contrast application.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou
Journal:  Eur Radiol       Date:  2005-02       Impact factor: 5.315

5.  Multislice computed tomography for preoperative evaluation of right ventricular volumes and function: comparison with magnetic resonance imaging.

Authors:  Alexander Lembcke; Pascal M Dohmen; Marc Dewey; Christian Klessen; Thomas Elgeti; Kay-Geert A Hermann; Wolfgang F Konertz; Bernd Hamm; Dietmar E Kivelitz
Journal:  Ann Thorac Surg       Date:  2005-04       Impact factor: 4.330

6.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris.

Authors:  Francesca Pugliese; Nico R A Mollet; Giuseppe Runza; Carlos van Mieghem; Willem B Meijboom; Patrizia Malagutti; Timo Baks; Gabriel P Krestin; Pim J deFeyter; Filippo Cademartiri
Journal:  Eur Radiol       Date:  2005-11-16       Impact factor: 5.315

7.  Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time.

Authors:  Shi-Zheng Zhang; Xiu-Hua Hu; Qiao-Wei Zhang; Wen-Xin Huang
Journal:  Eur Radiol       Date:  2005-03-11       Impact factor: 5.315

8.  Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients.

Authors:  Stephen Schroeder; Andreas F Kopp; Axel Kuettner; Christof Burgstahler; Christian Herdeg; Martin Heuschmid; Andreas Baumbach; Claus D Claussen; Karl R Karsch; Ludger Seipel
Journal:  Clin Imaging       Date:  2002 Mar-Apr       Impact factor: 1.605

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

Review 10.  Preoperative assessment of cardiac patients undergoing noncardiac surgical procedures.

Authors:  W K Freeman; R J Gibbons; C Shub
Journal:  Mayo Clin Proc       Date:  1989-09       Impact factor: 7.616

View more
  5 in total

1.  Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction.

Authors:  Heon Lee; Jeong A Kim; Ji Sung Lee; Jon Suh; Sang Hyun Paik; Jai Soung Park
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-20       Impact factor: 2.357

2.  Subtraction magnetocardiogram for detecting coronary heart disease.

Authors:  Akihiko Kandori; Kuniomi Ogata; Tsuyoshi Miyashita; Hiroshi Takaki; Hideyuki Kanzaki; Syuji Hashimoto; Wataru Shimizu; Shiro Kamakura; Shigeyuki Watanabe; Kazutaka Aonuma
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

3.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

4.  Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

Authors:  Vittorio Pansini; Martine Remy-Jardin; Nunzia Tacelli; Jean-Baptiste Faivre; Thomas Flohr; Valérie Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2008-05-08       Impact factor: 5.315

5.  Ultrafast imaging of the entire chest without ECG synchronisation or beta-blockade: to what extent can we analyse the coronary arteries?

Authors:  Maxime de Malherbe; Alain Duhamel; Nunzia Tacelli; Anne-Lise Hachulla; François Pontana; Jean-Baptiste Faivre; Jacques Remy; Martine Remy-Jardin
Journal:  Insights Imaging       Date:  2011-11-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.