Literature DB >> 19244949

Induced astigmatism with 2.2- and 3.0-mm coaxial phacoemulsification incisions.

Samuel Masket1, Li Wang, Shaleen Belani.   

Abstract

PURPOSE: To evaluate the difference between 2.2-mm incision micro-coaxial phacoemulsification and traditional 3.0-mm coaxial phacoemulsification with respect to surgically induced astigmatism after temporally oriented clear corneal incision cataract surgery.
METHODS: This prospective, randomized, intra-patient controlled study comprised 22 patients who underwent clear corneal cataract surgery in both eyes. One eye received 2.2-mm incision micro-coaxial phacoemulsification with intraocular lens (IOL) implantation and the fellow eye received traditional 3.0-mm coaxial incision phacoemulsification with IOL implantation. The 2.2-mm incisions were created with a diamond keratome after a 200-microm groove was constructed in clear cornea at the temporal limbus. The 3.0-mm incisions were created without a pre-cut groove, using a metal keratome. All cases were uncomplicated. Pre- and postoperative keratometric astigmatism at 6 weeks was measured using a hand held Nikon Retinomax K-plus 2 Autorefractor. Three methods were used to analyze the surgically induced astigmatism (SIA) data: 1) algebraic analysis of the magnitude of keratometric astigmatism induced by the surgery, 2) magnitude of SIA by vector analysis, and 3) aggregate analysis of astigmatism using vector analysis.
RESULTS: The mean change in the magnitude of keratometric astigmatism was 0.10+/-0.08 diopters (D) with the 2.2-mm micro-coaxial incisions and 0.32+/-0.20 D with the 3.0-mm traditional incisions (P=.0002). Usingvector analysis, the mean magnitude of SIA was 0.35+/-0.21 D with the 2.2-mm incisions and 0.67+/-0.48 D (P=.006) with the 3.0-mm incisions.
CONCLUSIONS: Surgically induced astigmatism with 2.2-mm micro-coaxial incisions and traditional 3.0-mm clear corneal incisions with intra-patient control resulted in statistically and clinically significant reduction in surgically induced astigmatism with the smaller incision size.

Entities:  

Mesh:

Year:  2009        PMID: 19244949     DOI: 10.3928/1081597X-20090101-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  28 in total

1.  Astigmatic equivalence of 2.2-mm and 1.8-mm superior clear corneal cataract incision.

Authors:  Jean-Luc Febbraro; Li Wang; Edmondo Borasio; Lorenzo Richiardi; Hamza N Khan; Alain Saad; Damien Gatinel; Douglas D Koch
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-16       Impact factor: 3.117

2.  Clinical evaluation of surgery-induced astigmatism in cataract surgery using 2.2 mm or 1.8 mm clear corneal micro-incisions.

Authors:  Jun Yang; Xiu Wang; Hong Zhang; Yi Pang; Rui-Hua Wei
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

3.  Optimal incision sites to reduce corneal aberration variations after small incision phacoemulsification cataract surgery.

Authors:  Ling Chu; Jiang-Yue Zhao; Jin-Song Zhang; Jie Meng; Ming-Wu Wang; Ya-Jing Yang; Jia-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

4.  Changes in corneal aberrations after cataract surgery.

Authors:  Yuki Hidaka; Takefumi Yamaguchi; Megumi Saiki; Murat Dogru; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-02       Impact factor: 2.447

Review 5.  Different-sized incisions for phacoemulsification in age-related cataract.

Authors:  Chongfei Jin; Xinyi Chen; Andrew Law; Yunhee Kang; Xue Wang; Wen Xu; Ke Yao
Journal:  Cochrane Database Syst Rev       Date:  2017-09-20

6.  Innovative intraocular lens loading magnified.

Authors:  Rengaraj Venkatesh; Bharat Gurnani; Kirandeep Kaur
Journal:  Indian J Ophthalmol       Date:  2020-08       Impact factor: 1.848

7.  [Effect of different clear corneal incision sites on surgery efficacy and anterior segment parameters in patients undergoing phacoemulsification].

Authors:  Lijun Wang; Xiting Yang; Yi Zhang; Dingying Liao; Lin Zhao; Jianming Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-12-30

8.  Short-term outcomes of a modified technique for small-incision scleral-fixated intraocular lens implantation using Gore-Tex sutures.

Authors:  Ching-Wen Huang; Chia-Ying Tsai; Tso-Ting Lai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-04-29       Impact factor: 3.117

9.  Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

Authors:  S Khokhar; R Sharma; B Patil; N Aron; S Gupta
Journal:  Eye (Lond)       Date:  2014-07-18       Impact factor: 3.775

10.  Analyses of surgically induced astigmatism and axis deviation in microcoaxial phacoemulsification.

Authors:  Erhan Özyol; Pelin Özyol
Journal:  Int Ophthalmol       Date:  2013-10-01       Impact factor: 2.031

View more