Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: new motorized injector versus standard manual injector.

David Allen1, Maged Habib, David Steel.   

Abstract

PURPOSE: To assess the impact on incision size of IOL implantation using a new motorized intraocular lens (IOL) injector versus a standard manual injector.
SETTING: Cataract Treatment Centre, Sunderland Eye Infirmary, Sunderland, United Kingdom.
DESIGN: Comparative case series.
METHODS: All patients received an Acrysof SN60WF IOL implanted using a D cartridge and an Autosert motorized injector at fast speed, an Autosert motorized injector at slow speed, or a manual Monarch injector. Each group had a range of preimplantation incision sizes (1.9 mm, 2.0 mm, 2.1 mm, 2.2 mm, 2.3 mm). Incision gauges were used to measure the incision width before and immediately after IOL implantation.
RESULTS: The study recruited 256 patients. All incisions that were 1.8 mm at the commencement of surgery increased in size by the end of irrigation/aspiration. The motorized injector used with a fast speed (4.4 mm/sec) caused significantly less incision enlargement than the manual injector for all preimplantation incision sizes tested (P<.02). For 4 of the 5 preimplantation incision size subgroups, the motorized injector used at slow speed (1.5 mm/sec) produced less incision stretch than the manual injector, although the difference did not reach statistical significance.
CONCLUSION: The motorized injector was easy to use, and its use with an injection speed of 4.4 mm/sec caused significantly less incision enlargement than the manual injector during IOL implantation.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22154012     DOI: 10.1016/j.jcrs.2011.08.038

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

Authors:  S Khokhar; R Sharma; B Patil; N Aron; S Gupta
Journal:  Eye (Lond)       Date:  2014-07-18       Impact factor: 3.775

2.  Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector.

Authors:  Hisanori Imai; Ayaka Fujii; Emiko Tani; Atsushi Azumi
Journal:  J Ophthalmol       Date:  2016-02-17       Impact factor: 1.909

3.  Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system.

Authors:  Javier Mendicute; Thierry Amzallag; Lixin Wang; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2018-08-21

4.  Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions.

Authors:  Tetsuro Oshika; Noriyuki Sasaki
Journal:  J Ophthalmol       Date:  2021-03-31       Impact factor: 1.909

5.  Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study.

Authors:  Lu Zhang; Sonja Schickhardt; Hui Fang; Florian Auerbach; Perfecto Cagampang; Patrick R Merz; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2022-02-01       Impact factor: 3.351

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.