Literature DB >> 24959737

Can a revised paediatric radiation dose reduction CT protocol be applied and still maintain anatomical delineation, diagnostic confidence and overall imaging quality?

S Kritsaneepaiboon1, P Siriwanarangsun, P Tanaanantarak, A Krisanachinda.   

Abstract

OBJECTIVE: To compare multidetector CT (MDCT) radiation doses between default settings and a revised dose reduction protocol and to determine whether the diagnostic confidence can be maintained with imaging quality made under the revised protocol in paediatric head, chest and abdominal CT studies.
METHODS: The study retrospectively reviewed head, chest, abdominal and thoracoabdominal MDCT studies, comparing 231 CT studies taken before (Phase 1) and 195 CT studies taken after (Phase 2) the implemented revised protocol. Image quality was assessed using a five-point grading scale based on anatomical criteria, diagnostic confidence and overall quality. Image noise and dose-length product (DLP) were collected and compared.
RESULTS: The relative dose reductions between Phase 1 and Phase 2 were statistically significant in 35%, 51% and 54% (p < 0.001) of head, chest and abdominal CT studies, respectively. There were no statistically significant differences in overall image quality score comparisons in the head (p = 0.3), chest (p = 0.7), abdominal (p = 0.7) and contiguous thoracic (p = 0.1) and abdominal (p = 0.2) CT studies, with the exception of anatomical quality in definition of bronchial walls and delineation of intrahepatic portal branches in thoracoabdominal CTs, and diagnostic confidence in mass lesion in head CTs, liver lesion (>1 cm), splanchnic venous thrombosis, pancreatitis in abdominal CTs, and emphysema and aortic dissection in thoracoabdominal CTs.
CONCLUSION: Paediatric CT radiation doses can be significantly reduced from manufacturer's default protocol while still maintaining anatomical delineation, diagnostic confidence and overall imaging quality. ADVANCES IN KNOWLEDGE: Revised paediatric CT protocol can provide a half DLP reduction while preserving overall imaging quality.

Entities:  

Mesh:

Year:  2014        PMID: 24959737      PMCID: PMC4453137          DOI: 10.1259/bjr.20140032

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  34 in total

1.  Quality initiatives: CT radiation dose reduction: how to implement change without sacrificing diagnostic quality.

Authors:  Eric P Tamm; X John Rong; Dianna D Cody; Randy D Ernst; Nancy E Fitzgerald; Vikas Kundra
Journal:  Radiographics       Date:  2011-10-03       Impact factor: 5.333

2.  Paediatric CT reference doses based on weight and CT dosimetry phantom size: local experience using a 64-slice CT scanner.

Authors:  Debbie J Watson; Kerry S Coakley
Journal:  Pediatr Radiol       Date:  2010-01-13

3.  Optimization of kilovoltage and tube current-exposure time product based on abdominal circumference: an oval phantom study for pediatric abdominal CT.

Authors:  Frank Dong; William Davros; Jessica Pozzuto; Janet Reid
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

4.  Survey of pediatric MDCT radiation dose from university hospitals in Thailand: a preliminary for national dose survey.

Authors:  Supika Kritsaneepaiboon; Panruethai Trinavarat; Pannee Visrutaratna
Journal:  Acta Radiol       Date:  2012-07-20       Impact factor: 1.990

5.  CT scanning: patterns of use and dose.

Authors:  F A Mettler; P W Wiest; J A Locken; C A Kelsey
Journal:  J Radiol Prot       Date:  2000-12       Impact factor: 1.394

6.  Optimization of kVp and mAs for pediatric low-dose simulated abdominal CT: is it best to base parameter selection on object circumference?

Authors:  Janet Reid; Jessica Gamberoni; Frank Dong; William Davros
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

7.  Patient doses in paediatric CT: feasibility of setting diagnostic reference levels.

Authors:  H Järvinen; K Merimaa; R Seuri; E Tyrväinen; M Perhomaa; P Savikurki-Heikkilä; E Svedström; J Ziliukas; M Lintrop
Journal:  Radiat Prot Dosimetry       Date:  2011-07-21       Impact factor: 0.972

Review 8.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen
Journal:  Pediatr Radiol       Date:  2010-06-10

9.  Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Michael A Moore; Randheer Shailam; Bob Liu; Thomas L Toth; Ellen Grant; Sjirk J Westra
Journal:  Radiology       Date:  2009-05-12       Impact factor: 11.105

10.  Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study.

Authors:  Mark S Pearce; Jane A Salotti; Mark P Little; Kieran McHugh; Choonsik Lee; Kwang Pyo Kim; Nicola L Howe; Cecile M Ronckers; Preetha Rajaraman; Alan W Sir Craft; Louise Parker; Amy Berrington de González
Journal:  Lancet       Date:  2012-06-07       Impact factor: 79.321

View more