Literature DB >> 19435938

Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies.

Sarabjeet Singh1, Mannudeep K Kalra, Michael A Moore, Randheer Shailam, Bob Liu, Thomas L Toth, Ellen Grant, Sjirk J Westra.   

Abstract

PURPOSE: To assess compliance and resultant radiation dose reduction with new pediatric chest and abdominal computed tomographic (CT) protocols based on patient weight, clinical indication, number of prior CT studies, and automatic exposure control.
MATERIALS AND METHODS: The study was institutional review board approved and HIPAA compliant. Informed consent was waived. The new pediatric CT protocols, which were organized into six color zones based on clinical indications and number of prior CT examinations in a given patient, were retrospectively assessed. Scanning parameters were adjusted on the basis of patient weight. For gradual dose reduction, pediatric CT (n = 692) examinations were performed in three phases of incremental stepwise dose reduction during a 17-month period. There were 245 male patients and 193 female patients (mean age, 12.6 years). Two radiologists independently reviewed CT images for image quality. Data were analyzed by using multivariate analysis of variance.
RESULTS: Compliance with the new protocols in the early stage of implementation (chest CT, 58.9%; abdominal CT, 65.2%) was lower than in the later stage (chest CT, 88%; abdominal CT, 82%) (P < .001). For chest CT, there was 52.6% (9.1 vs 19.2 mGy) to 85.4% (2.8 vs 19.2 mGy) dose reduction in the early stage of implementation and 73.5% (4.9 vs 18.5 mGy) to 83.2% (3.1 vs 18.5 mGy) dose reduction in the later stages compared with dose at noncompliant examinations (P < .001); there was no loss of clinically relevant image quality. For abdominal CT, there was 34.3% (9.0 vs 13.7 mGy) to 80.2% (2.7 vs 13.7 mGy) dose reduction in the early stage of implementation and 62.4% (6.5 vs 17.3) to 83.8% (2.8 vs 17.3 mGy) dose reduction in the later stage (P < .001).
CONCLUSION: Substantial dose reduction and high compliance can be obtained with pediatric CT protocols tailored to clinical indications, patient weight, and number of prior studies. (c) RSNA, 2009.

Entities:  

Mesh:

Year:  2009        PMID: 19435938     DOI: 10.1148/radiol.2521081554

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  59 in total

1.  Barriers to the enrollment of children in the Children's Oncology Group study of very low risk Wilms tumor: a report from the Children's Oncology Group.

Authors:  Conrad V Fernandez; Ning Li; Elizabeth A Mullen; Paul E Grundy; Elizabeth J Perman; Robert C Shamberger; Peter F Ehrlich; Jeffrey S Dome
Journal:  J Pediatr Hematol Oncol       Date:  2011-10       Impact factor: 1.289

2.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

3.  The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography.

Authors:  Joana Santos; Shane Foley; Graciano Paulo; Mark F McEntee; Louise Rainford
Journal:  Pediatr Radiol       Date:  2015-08-05

4.  Low-dose temporal bone CT in infants and young children: effective dose and image quality.

Authors:  C B Nauer; A Rieke; C Zubler; C Candreia; A Arnold; P Senn
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

5.  Paediatric CT reference doses based on weight and CT dosimetry phantom size: local experience using a 64-slice CT scanner.

Authors:  Debbie J Watson; Kerry S Coakley
Journal:  Pediatr Radiol       Date:  2010-01-13

Review 6.  Advances in CT technology and application to pediatric imaging.

Authors:  Mahadevappa Mahesh
Journal:  Pediatr Radiol       Date:  2011-08-17

7.  Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2011-06-07

8.  Prioritizing examination-centered over patient-centered dose reduction: a hazard of institutional "benchmarking".

Authors:  Jonathan D Eisenberg; Michael E Gilmore; Mannudeep K Kalra; Chung Yin Kong; Pari V Pandharipande
Journal:  AJR Am J Roentgenol       Date:  2014-05       Impact factor: 3.959

9.  Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections.

Authors:  Ronald J Viola; Giao B Nguyen; Terry T Yoshizumi; Sandra S Stinnett; Jenny K Hoang; Peter G Kranz
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

Review 10.  Multidetector CT in children: current concepts and dose reduction strategies.

Authors:  Rutger A J Nievelstein; Ingrid M van Dam; Aart J van der Molen
Journal:  Pediatr Radiol       Date:  2010-06-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.