Literature DB >> 22821958

Survey of pediatric MDCT radiation dose from university hospitals in Thailand: a preliminary for national dose survey.

Supika Kritsaneepaiboon1, Panruethai Trinavarat, Pannee Visrutaratna.   

Abstract

BACKGROUND: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation.
PURPOSE: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP).
MATERIAL AND METHODS: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDI(vol)) and DLP were recorded, categorized into four age groups: <1 year, 1-< 5 years, 5-<10 years, and 10-<15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDI(vol): 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm.
CONCLUSION: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDI(vol) and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

Entities:  

Mesh:

Year:  2012        PMID: 22821958     DOI: 10.1258/ar.2012.110641

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  12 in total

1.  Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan.

Authors:  Yasutaka Takei; Osamu Miyazaki; Kosuke Matsubara; Yoshiya Shimada; Yoshihisa Muramatsu; Keiichi Akahane; Keisuke Fujii; Shoichi Suzuki; Kichiro Koshida
Journal:  Pediatr Radiol       Date:  2016-02

2.  Survey of volume CT dose index in Japan in 2014.

Authors:  Y Matsunaga; A Kawaguchi; K Kobayashi; Y Kinomura; M Kobayashi; Y Asada; K Minami; S Suzuki; K Chida
Journal:  Br J Radiol       Date:  2015-06-04       Impact factor: 3.039

3.  Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

Authors:  Peter K T Hui; Hyun Woo Goo; Jing Du; Janice J K Ip; Suzu Kanzaki; Young Jin Kim; Supika Kritsaneepaiboon; Oktavia Lilyasari; Suvipaporn Siripornpitak
Journal:  Pediatr Radiol       Date:  2017-04-24

4.  Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT.

Authors:  Remy-Jardin Martine; Teresa Santangelo; Lucie Colas; Faivre Jean-Baptiste; Alain Duhamel; Antoine Deschildre; Jacques Remy
Journal:  Pediatr Radiol       Date:  2016-11-09

5.  Can a revised paediatric radiation dose reduction CT protocol be applied and still maintain anatomical delineation, diagnostic confidence and overall imaging quality?

Authors:  S Kritsaneepaiboon; P Siriwanarangsun; P Tanaanantarak; A Krisanachinda
Journal:  Br J Radiol       Date:  2014-06-24       Impact factor: 3.039

6.  Individual radiation exposure from computed tomography: a survey of paediatric practice in French university hospitals, 2010-2013.

Authors:  Neige M Y Journy; Serge Dreuil; Nathalie Boddaert; Jean-François Chateil; Didier Defez; Hubert Ducou-le-Pointe; Jean-Marc Garcier; Joël Guersen; Bouchra Habib Geryes; Andreas Jahnen; Choonsik Lee; Jacqueline Payen-de-la-Garanderie; Jean-Pierre Pracros; Dominique Sirinelli; Isabelle Thierry-Chef; Marie-Odile Bernier
Journal:  Eur Radiol       Date:  2017-08-23       Impact factor: 5.315

7.  Local diagnostic reference level based on size-specific dose estimates: assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children's hospital.

Authors:  Rumi Imai; Osamu Miyazaki; Tetsuya Horiuchi; Hideo Kurosawa; Shunsuke Nosaka
Journal:  Pediatr Radiol       Date:  2014-10-09

8.  Nationwide radiation dose survey of computed tomography for fetal skeletal dysplasias.

Authors:  Osamu Miyazaki; Hideaki Sawai; Jun Murotsuki; Gen Nishimura; Tetsuya Horiuchi
Journal:  Pediatr Radiol       Date:  2014-04-16

9.  Diagnostic value of CT compared to ultrasound in the evaluation of acute abdominal pain in children younger than 10 years old.

Authors:  Natalia Simanovsky; Tamar Dola; Nurith Hiller
Journal:  Emerg Radiol       Date:  2015-10-09

10.  A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning.

Authors:  Jae-Yeon Hwang; Kyung-Hyun Do; Dong Hyun Yang; Young Ah Cho; Hye-Kyung Yoon; Jin Seong Lee; Hyun Jung Koo
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817