DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators.

Samuel España1, Radoslaw Marcinkowski, Vincent Keereman, Stefaan Vandenberghe, Roel Van Holen.   

Abstract

A new preclinical PET system based on dSiPMs, called DigiPET, is presented. The system is based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low-cost compared to systems based on pixelated crystals. Current dedicated small-rodent PET scanners have a spatial resolution in the order of 1 mm. Most of them have a large footprint, requiring considerable laboratory space. For rodent brain imaging, a PET scanner with sub-millimeter resolution is desired. To achieve this, crystals with a pixel pitch down to 0.5 mm have been used. However, fine pixels are difficult to produce and will render systems expensive. In this work, we present the first results with a high-resolution preclinical PET scanner based on thin monolithic scintillators and a large solid angle. The design is dedicated to rat-brain imaging and therefore has a very compact geometry. Four detectors were placed in a square arrangement with a distance of 34.5 mm between two opposing detector modules, defining a field of view (FOV) of 32 × 32 × 32 mm(3). Each detector consists of a thin monolithic LYSO crystal of 32 × 32 × 2 mm(3) optically coupled to a digital silicon photomultiplier (dSiPM). Event positioning within each detector was obtained using the maximum likelihood estimation (MLE) method. To evaluate the system performance, we measured the energy resolution, coincidence resolving time (CRT), sensitivity and spatial resolution. The image quality was evaluated by acquiring a hot-rod phantom filled with (18)F-FDG and a rat head one hour after an (18)F-FDG injection. The MLE yielded an average intrinsic spatial resolution on the detector of 0.54 mm FWHM. We obtained a CRT of 680 ps and an energy resolution of 18% FWHM at 511 keV. The sensitivity and spatial resolution obtained at the center of the FOV were 6.0 cps kBq(-1) and 0.7 mm, respectively. In the reconstructed images of the hot-rod phantom, hot rods down to 0.7 mm can be discriminated. In conclusion, a compact PET scanner was built using dSiPM technology and thin monolithic LYSO crystals. Excellent spatial resolution and acceptable sensitivity were demonstrated. Promising results were also obtained in a hot-rod phantom and in rat-brain imaging.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24888974     DOI: 10.1088/0031-9155/59/13/3405

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

Review 1.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

2.  Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.

Authors:  Jung Yeol Yeom; Ruud Vinke; Craig S Levin
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

3.  Modularized compact positron emission tomography detector for rapid system development.

Authors:  Daoming Xi; Xiang Liu; Chen Zeng; Wei Liu; Yanzhao Li; Yuexuan Hua; Xiongze Mei; Heejong Kim; Peng Xiao; Chien-Min Kao; Qingguo Xie
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-20

4.  Preclinical positron emission tomography scanner based on a monolithic annulus of scintillator: initial design study.

Authors:  Alexander V Stolin; Peter F Martone; Gangadhar Jaliparthi; Raymond R Raylman
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-05

5.  Effect of CZT system characteristics on Compton scatter event recovery.

Authors:  Sheng Yang; Mohan Li; Michael Reed; James Hugg; Henry Chen; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-06

6.  PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator.

Authors:  Julie Bolcaen; Benedicte Descamps; Tom Boterberg; Christian Vanhove; Ingeborg Goethals
Journal:  J Vis Exp       Date:  2017-12-28       Impact factor: 1.355

7.  A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging.

Authors:  Yongfeng Yang; Julien Bec; Jian Zhou; Mengxi Zhang; Martin S Judenhofer; Xiaowei Bai; Kun Di; Yibao Wu; Mercedes Rodriguez; Purushottam Dokhale; Kanai S Shah; Richard Farrell; Jinyi Qi; Simon R Cherry
Journal:  J Nucl Med       Date:  2016-03-24       Impact factor: 10.057

8.  Characterization of highly multiplexed monolithic PET / gamma camera detector modules.

Authors:  L A Pierce; S Pedemonte; D DeWitt; L MacDonald; W C J Hunter; K Van Leemput; R Miyaoka
Journal:  Phys Med Biol       Date:  2018-03-29       Impact factor: 3.609

9.  Evaluation of event position reconstruction in monolithic crystals that are optically coupled.

Authors:  M Morrocchi; W C J Hunter; A Del Guerra; T K Lewellen; P E Kinahan; L R MacDonald; M G Bisogni; R S Miyaoka
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

10.  Quantitative 4D-PET reconstruction for small animal using SMEIR-reconstructed 4D-CBCT.

Authors:  Yuncheng Zhong; Faraz Kalantari; You Zhang; Yiping Shao; Jing Wang
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-03-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.