Dosimetric audit in brachytherapy.

A L Palmer1, D A Bradley, A Nisbet.   

Abstract

Dosimetric audit is required for the improvement of patient safety in radiotherapy and to aid optimization of treatment. The reassurance that treatment is being delivered in line with accepted standards, that delivered doses are as prescribed and that quality improvement is enabled is as essential for brachytherapy as it is for the more commonly audited external beam radiotherapy. Dose measurement in brachytherapy is challenging owing to steep dose gradients and small scales, especially in the context of an audit. Several different approaches have been taken for audit measurement to date: thimble and well-type ionization chambers, thermoluminescent detectors, optically stimulated luminescence detectors, radiochromic film and alanine. In this work, we review all of the dosimetric brachytherapy audits that have been conducted in recent years, look at current audits in progress and propose required directions for brachytherapy dosimetric audit in the future. The concern over accurate source strength measurement may be essentially resolved with modern equipment and calibration methods, but brachytherapy is a rapidly developing field and dosimetric audit must keep pace.

Entities:  

Mesh:

Year:  2014        PMID: 24807068      PMCID: PMC4453142          DOI: 10.1259/bjr.20140105

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  35 in total

1.  Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources.

Authors:  D Baltas; K Geramani; G T Ioannidis; K Hierholz; B Rogge; C Kolotas; K Müller-Sievers; N Milickovic; B Kober; N Zamboglou
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-02-01       Impact factor: 7.038

2.  Determination of the accuracy of implant reconstruction and dose delivery in brachytherapy in The Netherlands and Belgium.

Authors:  R J Elfrink; I K Kolkman-Deurloo; H J van Kleffens; A Rijnders; B Schaeken; T H Aalbers; W J Dries; J L Venselaar
Journal:  Radiother Oncol       Date:  2001-06       Impact factor: 6.280

3.  A new re-entrant ionization chamber for the calibration of iridium-192 high dose rate sources.

Authors:  S J Goetsch; F H Attix; L A DeWerd; B R Thomadsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  1992       Impact factor: 7.038

4.  Audit on source strength determination for HDR and PDR (192)Ir brachytherapy in Sweden.

Authors:  Asa Carlsson Tedgren; Jan-Erik Grindborg
Journal:  Radiother Oncol       Date:  2008-01-09       Impact factor: 6.280

Review 5.  Anniversary paper: past and current issues, and trends in brachytherapy physics.

Authors:  Bruce R Thomadsen; Jeffrey F Williamson; Mark J Rivard; Ali S Meigooni
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

6.  A dosimetric intercomparison of electron beams in UK radiotherapy centres.

Authors:  A Nisbet; D I Thwaites
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

7.  In-phantom calibration of Selectron-LDR sources.

Authors:  H Meertens
Journal:  Radiother Oncol       Date:  1990-04       Impact factor: 6.280

8.  Intercomparison of calibration procedures for Ir-192 HDR sources in The Netherlands and Belgium.

Authors:  J L Venselaar; W F Brouwer; B H van Straaten; A H Aalbers
Journal:  Radiother Oncol       Date:  1994-02       Impact factor: 6.280

9.  Recommendations for safer radiotherapy: what's the message?

Authors:  Peter Dunscombe
Journal:  Front Oncol       Date:  2012-09-28       Impact factor: 6.244

10.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30
View more
  3 in total

Review 1.  Electronic brachytherapy--current status and future directions.

Authors:  D J Eaton
Journal:  Br J Radiol       Date:  2015-03-06       Impact factor: 3.039

2.  The Design of an Audit Test for 60Co Brachytherapy Treatment Planning System.

Authors:  Mohammad Javad Tahmasebi Birgani; Hadis Khorshidsavar; Ali Bagheri; Amir Danyaei; Neda Abdalvand
Journal:  J Med Signals Sens       Date:  2022-05-12

3.  Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Authors:  Catharine H Clark; Edwin G A Aird; Steve Bolton; Elizabeth A Miles; Andrew Nisbet; Julia A D Snaith; Russell A S Thomas; Karen Venables; David I Thwaites
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.