Literature DB >> 9434296

A dosimetric intercomparison of electron beams in UK radiotherapy centres.

A Nisbet1, D I Thwaites.   

Abstract

A dosimetry intercomparison has been carried out for all 52 radiotherapy centres in the UK which possess electron treatment facilities. The intercomparison was carried out on one treatment unit in each centre and for three energies across the range of available energies. The position of the depth of maximum dose for a standard field size was independently determined and a subsequent beam calibration made. The factor to convert the reading on a calibrated ionization chamber to absorbed dose in an electron beam is energy dependent, and hence to carry out an independent calibration measurement also requires the beam energy to be determined. In addition a quantitative measure of the difference in the calibration chains between the intercomparison equipment and the host department's field instrument was carried out. In order to provide a follow-up to the initial IPSM national photon intercomparison, a photon beam calibration was measured in one photon beam in each centre. For 156 electron beam measurements, a mean ratio of intercomparison measured dose to locally measured dose of 0.994 was obtained with a standard deviation of 1.8%. For the 52 photon beam measurements, a mean ratio of intercomparison measured dose to locally measured dose of 1.003 was obtained with a standard deviation of 1.0%.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9434296     DOI: 10.1088/0031-9155/42/12/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Analysis of regional radiotherapy dosimetry audit data and recommendations for future audits.

Authors:  A Palmer; B Mzenda; J Kearton; R Wills
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  A national dosimetry audit of intraoperative radiotherapy.

Authors:  D J Eaton; B Earner; P Faulkner; N Dancer
Journal:  Br J Radiol       Date:  2013-10-16       Impact factor: 3.039

Review 3.  Dosimetric audit in brachytherapy.

Authors:  A L Palmer; D A Bradley; A Nisbet
Journal:  Br J Radiol       Date:  2014-05-06       Impact factor: 3.039

4.  Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Authors:  Catharine H Clark; Edwin G A Aird; Steve Bolton; Elizabeth A Miles; Andrew Nisbet; Julia A D Snaith; Russell A S Thomas; Karen Venables; David I Thwaites
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

5.  Inter-departmental dosimetry audits - development of methods and lessons learned.

Authors:  David J Eaton; Steve Bolton; Russell A S Thomas; Catharine H Clark
Journal:  J Med Phys       Date:  2015 Oct-Dec

6.  Remote beam output audits: a global assessment of results out of tolerance.

Authors:  Stephen F Kry; Christine B Peterson; Rebecca M Howell; Joanna Izewska; Jessica Lye; Catharine H Clark; Mitsuhiro Nakamura; Coen Hurkmans; Paola Alvarez; Andrew Alves; Tomislav Bokulic; David Followill; Pavel Kazantsev; Jessica Lowenstein; Andrea Molineu; Jacob Palmer; Susan A Smith; Paige Taylor; Paulina Wesolowska; Ivan Williams
Journal:  Phys Imaging Radiat Oncol       Date:  2018-09-16

7.  An on-site dosimetry audit for high-energy electron beams.

Authors:  Leon de Prez; Stan Heukelom; Bartel Jansen; Wim Jansen; Jeroen van de Kamer; Wenze van Klink; Elfried Kok; Thijs Perik; Jacco de Pooter; Frits Wittkämper
Journal:  Phys Imaging Radiat Oncol       Date:  2018-02-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.