Effect of structural remodeling (retraction and recoil) of the pipeline embolization device on aneurysm occlusion rate.

L-D Jou1, B D Mitchell2, H M Shaltoni3, M E Mawad3.   

Abstract

BACKGROUND AND
PURPOSE: During endovascular treatment of unruptured aneurysms with the Pipeline Embolization Device, an oversized device is often selected to achieve better wall apposition; however, this device oversizing could be related to overelongation and possible delayed enlargement of the stented region. The purpose of this study is to investigate the relationship between oversize and treatment outcome.
MATERIALS AND METHODS: The DynaCT images of 14 aneurysms treated by a single Pipeline Embolization Device were retrospectively analyzed. 3D images of the deployed device were compared with those acquired at the 6-month follow-up for qualitative and quantitative evaluation. The diameter and length of the Pipeline Embolization Device were measured at both time points and compared for determination of the device changes.
RESULTS: Structural changes of the device have been observed, and it was found that the Pipeline Embolization Device influences the vessel curvature in some cases. On average, it increases its diameter by 0.23 mm and decreases its length by 2.88 mm within 6 months of initial deployment. Excessive elongation beyond its nominal length is correlated with a lower aneurysm occlusion rate at the 6-month follow-up.
CONCLUSIONS: Not only does a Pipeline Embolization Device reconstruct the aneurysm and parent artery, but its entire structure goes through a gradual remodeling process. The relative deformation between the device and the artery indicates suboptimal wall apposition. Device oversizing does not have a direct effect on shortening or recoil. The aneurysm occlusion rate, however, is lowered by overelongation of the Pipeline Embolization Device.
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2014        PMID: 24722301      PMCID: PMC7966279          DOI: 10.3174/ajnr.A3920

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  26 in total

1.  Physical properties of endovascular stents: an experimental comparison.

Authors:  S H Duda; J Wiskirchen; G Tepe; M Bitzer; T W Kaulich; D Stoeckel; C D Claussen
Journal:  J Vasc Interv Radiol       Date:  2000-05       Impact factor: 3.464

2.  Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms.

Authors:  Frédéric Clarençon; Michel Piotin; Silvia Pistocchi; Drazenko Babic; Raphaël Blanc
Journal:  Neuroradiology       Date:  2012-02-04       Impact factor: 2.804

3.  Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

Authors:  N Ebrahimi; B Claus; C-Y Lee; A Biondi; G Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

4.  Spatial resolution limits of multislice computed tomography (MS-CT), C-arm-CT, and flat panel-CT (FP-CT) compared to MicroCT for visualization of a small metallic stent.

Authors:  Mircea Ionescu; Ralph W Metcalfe; Dianna Cody; Miguel Valdivia Y Alvarado; John Hipp; Goetz Benndorf
Journal:  Acad Radiol       Date:  2011-07       Impact factor: 3.173

5.  Intracranial aneurysms: midterm outcome of pipeline embolization device--a prospective study in 143 patients with 178 aneurysms.

Authors:  Simon Chun-Ho Yu; Ching-Kwong Kwok; Pui-Wai Cheng; Kwong-Yau Chan; Samuel Shun Lau; Wai-Man Lui; Ka-Ming Leung; Raymand Lee; Harold Kin-Ming Cheng; Yuk-Ling Cheung; Chi-Ming Chan; George Kwok-Chu Wong; Joyce Wai-Yi Hui; Yiu-Chung Wong; Chong-Boon Tan; Wai-Lun Poon; Kai-Yuen Pang; Alain Kai-Sing Wong; Kai-Hung Fung
Journal:  Radiology       Date:  2012-09-20       Impact factor: 11.105

6.  Effects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms.

Authors:  F Mut; J R Cebral
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

7.  Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size.

Authors:  Shahid Aziz; John L Morris; Raphael A Perry; Rodney H Stables
Journal:  Heart       Date:  2007-05-04       Impact factor: 5.994

8.  The utility of DynaCT in neuroendovascular procedures.

Authors:  N S Heran; J K Song; K Namba; W Smith; Y Niimi; A Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

9.  Effects of overexpansion on stents' recoil, symmetry/asymmetry, and neointimal hyperplasia in aortas of hypercholesterolemic rabbits.

Authors:  Daniel H Berrocal; Germán E González; Alejandro Fernández; Susana Perez; Luciana Wilensky; Celina Morales; Liliana Grinfeld; Ricardo J Gelpi
Journal:  Cardiovasc Pathol       Date:  2008-02-19       Impact factor: 2.185

10.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

View more
  6 in total

1.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

Review 2.  Emerging Technologies in Flow Diverters and Stents for Cerebrovascular Diseases.

Authors:  Michael Karsy; Jian Guan; Andrea A Brock; Anubhav Amin; Min S Park
Journal:  Curr Neurol Neurosci Rep       Date:  2017-10-28       Impact factor: 5.081

3.  Is there an association between flow diverter fish mouthing and delayed-type hypersensitivity to metals?-a case-control study.

Authors:  Naci Kocer; Prabath Kumar Mondel; Elif Yamac; Ayse Kavak; Osman Kizilkilic; Civan Islak
Journal:  Neuroradiology       Date:  2017-09-05       Impact factor: 2.804

4.  Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check.

Authors:  Liang-Der Jou; Gouthami Chintalapani; Michel E Mawad
Journal:  Interv Neuroradiol       Date:  2015-11-30       Impact factor: 1.610

5.  Two- to five-year follow-up of 78 patients after treatment with the Flow Redirection Endoluminal Device.

Authors:  Hannes Luecking; Arnd Doerfler; Philipp Goelitz; Philip Hoelter; Tobias Engelhorn; Stefan Lang
Journal:  Interv Neuroradiol       Date:  2019-10-09       Impact factor: 1.610

Review 6.  Mechanism of Action and Biology of Flow Diverters in the Treatment of Intracranial Aneurysms.

Authors:  Krishnan Ravindran; Amanda M Casabella; Juan Cebral; Waleed Brinjikji; David F Kallmes; Ram Kadirvel
Journal:  Neurosurgery       Date:  2020-01-01       Impact factor: 4.654

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.