Literature DB >> 24691631

Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology.

Tobias Struffert1, Michael Hauer, Rosemarie Banckwitz, Christoph Köhler, Kevin Royalty, Arnd Doerfler.   

Abstract

PURPOSE: Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols.
METHODS: Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer.
RESULTS: (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv.
CONCLUSION: The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. KEY POINTS: Effective dose of FD-CT in comparison to MSCT is in comparable range. Collimation decreases the dose of FD-CT effectively. Effective dose of 3-D angiography is identical to 2-D DSA. Different FD-CT programs have different dose.

Entities:  

Mesh:

Year:  2014        PMID: 24691631     DOI: 10.1007/s00330-014-3136-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

1.  Angiographic CT for intraprocedural monitoring of complex neuroendovascular procedures.

Authors:  J Pfaff; T Struffert; P Gölitz; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-05       Impact factor: 3.825

2.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results.

Authors:  Tobias Struffert; Stephan Kloska; Tobias Engelhorn; Yu Deuerling-Zheng; Sabine Ott; Marc Doelken; Marc Saake; Martin Köhrmann; Arnd Doerfler
Journal:  Eur Radiol       Date:  2010-08-14       Impact factor: 5.315

3.  Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens.

Authors:  Soenke H Bartling; Rajiv Gupta; Attila Torkos; Christian Dullin; Grabbe Eckhardt; Thomas Lenarz; Hartmut Becker; Timo Stöver
Journal:  Otol Neurotol       Date:  2006-06       Impact factor: 2.311

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

5.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

6.  Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses.

Authors:  Alessandro Bozzato; Tobias Struffert; Victoria Hertel; Heinrich Iro; Joachim Hornung
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

7.  Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom.

Authors:  Jijo Paul; B Krauss; R Banckwitz; W Maentele; R W Bauer; T J Vogl
Journal:  Eur J Radiol       Date:  2011-02-12       Impact factor: 3.528

8.  Radiation dose from 3D rotational X-ray imaging: organ and effective dose with conversion factors.

Authors:  Sangroh Kim; David Sopko; Greta Toncheva; David Enterline; Bruno Keijzers; Terry T Yoshizumi
Journal:  Radiat Prot Dosimetry       Date:  2011-09-16       Impact factor: 0.972

9.  Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

Authors:  S Diekmann; E Siebert; R Juran; M Roll; W Deeg; H-C Bauknecht; F Diekmann; R Klingebiel; G Bohner
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-28       Impact factor: 3.825

10.  Feasibility of flat panel detector computed tomography for position assessment of external ventricular drainage.

Authors:  Philipp von Gottberg; Marios Psychogios; Gunther Schuetze; Joseph Cohnen; Paul Zwaka; Michael Knauth; Peter Schramm
Journal:  Neurol Neurochir Pol       Date:  2013 Jan-Feb       Impact factor: 1.621

View more
  21 in total

1.  4D DSA for Dynamic Visualization of Cerebral Vasculature: A Single-Center Experience in 26 Cases.

Authors:  S Lang; P Gölitz; T Struffert; J Rösch; K Rössler; M Kowarschik; C Strother; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-13       Impact factor: 3.825

2.  An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

Authors:  Yinsheng Li; John W Garrett; Ke Li; Charles Strother; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2019-12-20       Impact factor: 10.048

3.  Are Flow Diverting Stents a Treatment Option in Acutely Ruptured Complex A1-A2 Junction Aneurysms?

Authors:  J Rösch; P Gölitz; T Struffert; M Köhrmann; A Doerfler
Journal:  Clin Neuroradiol       Date:  2015-05-24       Impact factor: 3.649

4.  Dynamic Angiography and Perfusion Imaging Using Flat Detector CT in the Angiography Suite: A Pilot Study in Patients with Acute Middle Cerebral Artery Occlusions.

Authors:  T Struffert; Y Deuerling-Zheng; S Kloska; T Engelhorn; S Lang; A Mennecke; M Manhart; C M Strother; S Schwab; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2015-06-11       Impact factor: 3.825

5.  One-Stop Management with Perfusion for Transfer Patients with Stroke due to a Large-Vessel Occlusion: Feasibility and Effects on In-Hospital Times.

Authors:  A Brehm; I Tsogkas; I L Maier; H J Eisenberger; P Yang; J-M Liu; J Liman; M-N Psychogios
Journal:  AJNR Am J Neuroradiol       Date:  2019-07-11       Impact factor: 3.825

6.  The Value of syngo DynaPBV Neuro During Neuro-Interventional Hypotensive Balloon Occlusion Test.

Authors:  M Yang; J Wu; L Ma; L Pan; J Li; G Chen; T Struffert; Q Sun; J Beilner; Y Deuerling-Zheng
Journal:  Clin Neuroradiol       Date:  2014-06-12       Impact factor: 3.649

7.  Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.

Authors:  Julie Rösch; Stefan Lang; Philipp Gölitz; Bernd Kallmünzer; Karl Rössler; Arnd Doerfler; Tobias Struffert
Journal:  Clin Neuroradiol       Date:  2017-05-05       Impact factor: 3.649

Review 8.  Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

Authors:  A Doerfler; P Gölitz; T Engelhorn; S Kloska; T Struffert
Journal:  Clin Neuroradiol       Date:  2015-06-20       Impact factor: 3.649

9.  Dose comparison of classical 2-plane DSA and 3D rotational angiography for the assessment of intracranial aneurysms.

Authors:  N Guberina; U Lechel; M Forsting; C Mönninghoff; U Dietrich; A Ringelstein
Journal:  Neuroradiology       Date:  2016-03-12       Impact factor: 2.804

10.  Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms?

Authors:  P Gölitz; T Struffert; I Kaschka; K Roessler; F Knossalla; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.