Literature DB >> 21926088

Radiation dose from 3D rotational X-ray imaging: organ and effective dose with conversion factors.

Sangroh Kim1, David Sopko, Greta Toncheva, David Enterline, Bruno Keijzers, Terry T Yoshizumi.   

Abstract

The purpose of this study was to measure organ doses and the effective dose (ED) using a three-dimensional rotational X-ray (3D-RX) system and to determine the ED conversion factor from the dose area product (DAP) for skull, spine and biliary protocols. A commercial 3D-RX imaging system was used to simulate the protocols with the adult female anthropomorphic phantom. Twenty MOSFET detectors were used to measure the absorbed doses at various organ locations. The ED was calculated for each protocol and the corresponding DAP was obtained. The skin dose was the highest for all the protocols. The second highest organ doses were those of the brain for the skull, the intestine for the spine and the kidney for the biliary protocol. The ED was 0.4-0.9, 4.2-8.4 and 3.2-4.6 mSv, and the ED conversion factor was 0.06-0.09, 0.18-0.31 and 0.13-0.23 mSv Gy(-1) cm(-2) for each protocol, respectively. This data may be used to estimate the patient ED for those protocols in the 3D-RX.

Entities:  

Mesh:

Year:  2011        PMID: 21926088     DOI: 10.1093/rpd/ncr369

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

Authors:  J Koivisto; D Schulze; J Wolff; D Rottke
Journal:  Dentomaxillofac Radiol       Date:  2014-08-21       Impact factor: 2.419

2.  Brain radiation doses to patients in an interventional neuroradiology laboratory.

Authors:  R M Sanchez; E Vano; J M Fernández; M Moreu; L Lopez-Ibor
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-13       Impact factor: 3.825

3.  Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology.

Authors:  Tobias Struffert; Michael Hauer; Rosemarie Banckwitz; Christoph Köhler; Kevin Royalty; Arnd Doerfler
Journal:  Eur Radiol       Date:  2014-04-02       Impact factor: 5.315

4.  Radiation dose reference card for interventional radiology procedures: Experience in a tertiary referral centre.

Authors:  Anna Varghese; Shyamkumar N Keshava; Vinu Moses; George Koshy; Suraj Mammen; Munawwar Ahmed; Roshan S Livingstone
Journal:  Indian J Radiol Imaging       Date:  2019-10-30

5.  Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

Authors:  Juha H Koivisto; Jan E Wolff; Timo Kiljunen; Dirk Schulze; Mika Kortesniemi
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102