Literature DB >> 25034780

Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms?

P Gölitz1, T Struffert2, I Kaschka2, K Roessler3, F Knossalla4, A Doerfler2.   

Abstract

BACKGROUND AND
PURPOSE: Because recanalization of coiled cerebral aneurysms is reported to occur, follow-up imaging is mandatory, ideally noninvasively. Our study aimed to evaluate the accuracy of an optimized angiographic CT by using intravenous contrast material injection in the assessment of coiled cerebral aneurysms, compared with MR angiography and digital subtraction angiography, the criterion standard.
MATERIALS AND METHODS: We included 69 patients with 76 coiled cerebral aneurysms. In each patient, we performed an angiographic CT with intravenous contrast material injection with a dual rotational acquisition, a time-of-flight MR angiography, and a DSA. The angiographic CT with intravenous contrast material injection data was postprocessed by using newly implemented reconstructions modes and a dual-volume technique. An aneurysm occlusion rate was assessed in angiographic CT with intravenous contrast material injection and MRA; remnants were measured and correlated with DSA, respectively.
RESULTS: Twenty-eight remnants were revealed by DSA with a mean size of 3.1 × 3.1 mm. Angiographic CT with intravenous contrast material injection demonstrated a sensitivity of 93% and a specificity of 96% in remnant detection. MRA showed almost identical accuracy (sensitivity of 93%, specificity of 100%). Assessment of remnant size by angiographic CT with intravenous contrast material injection and by MRA revealed a high significant correlation with DSA, respectively (P < .001).
CONCLUSIONS: Optimized angiographic CT with intravenous contrast material injection and MRA demonstrated accuracy comparable with that of DSA in the follow-up of coiled aneurysms, respectively. The assessment of remnant size showed a high correlation with DSA for both techniques. Due to the lack of radiation exposure, MRA seems to be the preferred technique. However, angiographic CT with intravenous contrast material injection can be considered a reliable, noninvasive alternative in patients with MR imaging contraindications or in cases of compromising artifacts due to metal implants (ie, clips).
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25034780      PMCID: PMC7965328          DOI: 10.3174/ajnr.A4039

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  20 in total

1.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results.

Authors:  Tobias Struffert; Stephan Kloska; Tobias Engelhorn; Yu Deuerling-Zheng; Sabine Ott; Marc Doelken; Marc Saake; Martin Köhrmann; Arnd Doerfler
Journal:  Eur Radiol       Date:  2010-08-14       Impact factor: 5.315

2.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model.

Authors:  Tobias Struffert; Sabine Ott; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Yu Deuerling-Zheng; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

3.  Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms.

Authors:  P Gölitz; T Struffert; F Knossalla; M Saake; S Ott; O Ganslandt; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

4.  The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms.

Authors:  Won-Sang Cho; Sam Soo Kim; Seung Jin Lee; Sung Hun Kim
Journal:  Acta Radiol       Date:  2013-09-03       Impact factor: 1.990

5.  Coil-treated aneurysms: decision making regarding additional treatment based on findings of MR angiography and intraarterial DSA.

Authors:  Joanna D Schaafsma; Birgitta K Velthuis; René van den Berg; Patrick A Brouwer; Charles B L M Majoie; Frederik Barkhof; Omid Eshghi; Gerard A P de Kort; Rob T H Lo; Marieke E S Sprengers; Willem-Jan van Rooij; Joseph C Bot; Gabriël J E Rinkel
Journal:  Radiology       Date:  2012-09-25       Impact factor: 11.105

6.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

7.  Optimized angiographic computed tomography with intravenous contrast injection: an alternative to conventional angiography in the follow-up of clipped aneurysms?

Authors:  Philipp Gölitz; Tobias Struffert; Oliver Ganslandt; Marc Saake; Hannes Lücking; Julie Rösch; Frauke Knossalla; Arnd Doerfler
Journal:  J Neurosurg       Date:  2012-04-20       Impact factor: 5.115

8.  Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight MR angiography at 3T and 1.5T in a large prospective series.

Authors:  L Pierot; C Portefaix; J-Y Gauvrit; A Boulin
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-07       Impact factor: 3.825

Review 9.  Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates.

Authors:  Sandra P Ferns; Marieke E S Sprengers; Willem Jan van Rooij; Gabriël J E Rinkel; Jeroen C van Rijn; Shandra Bipat; Menno Sluzewski; Charles B L M Majoie
Journal:  Stroke       Date:  2009-06-11       Impact factor: 7.914

10.  Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT).

Authors:  Adriana Campi; Najib Ramzi; Andrew J Molyneux; Paul E Summers; Richard S C Kerr; Mary Sneade; Julia A Yarnold; Joan Rischmiller; James V Byrne
Journal:  Stroke       Date:  2007-03-29       Impact factor: 7.914

View more
  4 in total

1.  Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.

Authors:  Julie Rösch; Stefan Lang; Philipp Gölitz; Bernd Kallmünzer; Karl Rössler; Arnd Doerfler; Tobias Struffert
Journal:  Clin Neuroradiol       Date:  2017-05-05       Impact factor: 3.649

Review 2.  Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke.

Authors:  A Doerfler; P Gölitz; T Engelhorn; S Kloska; T Struffert
Journal:  Clin Neuroradiol       Date:  2015-06-20       Impact factor: 3.649

Review 3.  Flat Detector CT with Cerebral Pooled Blood Volume Perfusion in the Angiography Suite: From Diagnostics to Treatment Monitoring.

Authors:  Thijs van der Zijden; Annelies Mondelaers; Maurits Voormolen; Tomas Menovsky; Maarten Niekel; Thomas Jardinet; Thomas Van Thielen; Olivier D'Archambeau; Paul M Parizel
Journal:  Diagnostics (Basel)       Date:  2022-08-13

4.  Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

Authors:  Rastislav Pjontek; Belgin Önenköprülü; Bernhard Scholz; Yiannis Kyriakou; Gerrit A Schubert; Omid Nikoubashman; Ahmed Othman; Martin Wiesmann; Marc A Brockmann
Journal:  J Neurointerv Surg       Date:  2015-09-07       Impact factor: 5.836

  4 in total