Literature DB >> 24660188

Computer technology applications in surgical implant dentistry: a systematic review.

Ali Tahmaseb, Daniel Wismeijer, Wim Coucke, Wiebe Derksen.   

Abstract

PURPOSE: To assess the literature on the accuracy and clinical performance of static computer-assisted implant surgery in implant dentistry.
MATERIALS AND METHODS: Electronic and manual literature searches were applied to collect information about (1) the accuracy and (2) clinical performance of static computer-assisted implant systems. Meta-regression analysis was performed to summarize the accuracy studies. Failure/complication rates were investigated using a generalized linear mixed model for binary outcomes and a logit link to model implant failure rate.
RESULTS: From 2,359 articles, 14 survival and 24 accuracy studies were included in this systematic review. Nine different static image guidance systems were involved. The meta-analysis of the accuracy (24 clinical and preclinical studies) revealed a total mean error of 1.12 mm (maximum of 4.5 mm) at the entry point measured in 1,530 implants and 1.39 mm at the apex (maximum of 7.1 mm) measured in 1,465 implants. For the 14 included survival studies (total of 1,941 implants) using static computer-assisted implant dentistry, the mean failure rate was 2.7% (0% to 10%) after an observation period of at least 12 months. In 36.4% of the treated cases, intraoperative or prosthetic complications were reported, which included: template fractures during the surgery, change of plan because of factors such as limited primary implant stability, need for additional grafting procedures, prosthetic screw loosening, prosthetic misfit, and prosthesis fracture.
CONCLUSION: Different levels of quantity and quality of evidence were available for static computer-assisted implant placement, with tight-fitting high implant survival rates after only 12 months of observation in different indications achieving a variable level of accuracy. Future long-term clinical data are necessary to identify clinical indications; detect accuracy; assess risk; and justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24660188     DOI: 10.11607/jomi.2014suppl.g1.2

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  56 in total

1.  Full digital workflow for implant-prosthetic rehabilitations: a case report.

Authors:  L Arcuri; C Lorenzi; F Cecchetti; F Germano; M Spuntarelli; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2016-07-23

2.  Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters.

Authors:  Lauren O L Bohner; Pedro Tortamano; Juliana Marotti
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

3.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

4.  Computer-aided flapless implant surgery and immediate loading. A technical note.

Authors:  Alfonso Baruffaldi; Pier Paolo Poli; Andrea Baruffaldi; Lorenzo Giberti; Maurizio Pigozzo; Carlo Maiorana
Journal:  Oral Maxillofac Surg       Date:  2016-04-05

Review 5.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

6.  3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Jens Dreyhaupt; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-01-22       Impact factor: 3.573

Review 7.  The management of traumatic tooth loss with dental implants: part 2. Severe trauma.

Authors:  D W Seymour; M Patel; L Carter; M Chan
Journal:  Br Dent J       Date:  2014-12       Impact factor: 1.626

Review 8.  Current status and applications of additive manufacturing in dentistry: A literature-based review.

Authors:  Mohd Javaid; Abid Haleem
Journal:  J Oral Biol Craniofac Res       Date:  2019-04-16

9.  Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam.

Authors:  George K Koch; Adam Hamilton; Kelly Wang; Laura Herschdorfer; Kyu Ha Lee; German O Gallucci; Bernard Friedland
Journal:  Dentomaxillofac Radiol       Date:  2018-11-08       Impact factor: 2.419

10.  Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study.

Authors:  Sigmar Schnutenhaus; Marie Wagner; Cornelia Edelmann; Ralph G Luthardt; Heike Rudolph
Journal:  Dent J (Basel)       Date:  2021-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.