Literature DB >> 28042423

Full digital workflow for implant-prosthetic rehabilitations: a case report.

L Arcuri1, C Lorenzi1, F Cecchetti1, F Germano1, M Spuntarelli1, A Barlattani1.   

Abstract

OBJECTIVES: The aim of the present study was to describe a proof of concept digital workflow for the implant-prosthetic treatment in partially edentate patients and evaluate its clinical performance.
METHODS: A 55-year-old woman with a Kennedy class III bilateral edentulism in the mandible has been selected for a computer guided implantology according with the Smart Fusion® protocol (NobelBiocare, Kloten, Switzerland). After the template-guided implant placement, an immediate loading of the implants has been performed. QuickTemp conical temporary abutments were selected to deliver immediately prefabricated cement-retained provisionals. Two months after an impression was taken with an intraoral digital scanner (3Shape Trios3, Copenhagen, Denmark). The provisional restoration optical scanning was used to transfer the functionalized prosthetic contour to be duplicated into the definitive porcelain fused to zirconia restoration cemented on customized titanium abutments.
RESULTS: A satisfying esthetic and functional result has been achieved. No biological and mechanical complications were recorded.
CONCLUSIONS: The investigated fully digital implant-prosthetic protocol provided a smooth, complication free and time effective treatment alternative to the conventional workflow. Besides the fully digital workflow allowed the surgical and prosthetic decision making and the communication within the dental team and with the patient. Further improvements heading to a direct match between the intraoral scan and the CBCT are strongly advised in order to create the so-called virtual patient.

Entities:  

Keywords:  computer-guided implant surgery; dental implant; digital impression; intraoral scanner; smart fusion

Year:  2016        PMID: 28042423      PMCID: PMC5159894          DOI: 10.11138/orl/2015.8.4.114

Source DB:  PubMed          Journal:  Oral Implantol (Rome)        ISSN: 1974-5648


  29 in total

Review 1.  Imaging technique selection for the preoperative planning of oral implants: a review of the literature.

Authors:  Charbel BouSerhal; Reinhilde Jacobs; Marc Quirynen; Daniel van Steenberghe
Journal:  Clin Implant Dent Relat Res       Date:  2002       Impact factor: 3.932

2.  Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography.

Authors:  D Schulze; M Heiland; H Thurmann; G Adam
Journal:  Dentomaxillofac Radiol       Date:  2004-03       Impact factor: 2.419

3.  Mechanical characterization of an innovative dental implant system.

Authors:  Maria Vittoria Diamanti; Barbara Del Curto; Alberto Barlattani; Patrizio Bollero; Liliana Ottria; Mariapia Pedeferri
Journal:  J Appl Biomater Biomech       Date:  2009 Jan-Apr

Review 4.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.

Authors:  David Schneider; Pascal Marquardt; Marcel Zwahlen; Ronald E Jung
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

5.  Computer-assisted planning of oral implant surgery: a three-dimensional approach.

Authors:  K Verstreken; J Van Cleynenbreugel; G Marchal; I Naert; P Suetens; D van Steenberghe
Journal:  Int J Oral Maxillofac Implants       Date:  1996 Nov-Dec       Impact factor: 2.804

6.  The combination of digital surface scanners and cone beam computed tomography technology for guided implant surgery using 3Shape implant studio software: a case history report.

Authors:  Alejandro Lanis; Orlando Álvarez Del Canto
Journal:  Int J Prosthodont       Date:  2015 Mar-Apr       Impact factor: 1.681

7.  CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach.

Authors:  A Pozzi; M Gargari; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

8.  Accuracy of digital impressions of multiple dental implants: an in vitro study.

Authors:  Stefan Vandeweghe; Valentin Vervack; Melissa Dierens; Hugo De Bruyn
Journal:  Clin Oral Implants Res       Date:  2016-05-06       Impact factor: 5.977

9.  Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year.

Authors:  M Gargari; V Prete; M Pujia; F M Ceruso
Journal:  Oral Implantol (Rome)       Date:  2013-03-19

10.  CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient.

Authors:  Christopher B Marchack
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

View more
  3 in total

1.  Postextraction computer-guided implant surgery in partially edentate patients with metal restorations: a case report.

Authors:  A Pinto; C Raffone
Journal:  Oral Implantol (Rome)       Date:  2017-04-10

2.  In vitro evaluation of the post-space depth reading with an intraoral scanner (IOS) compared to a traditional silicon impression.

Authors:  A Pinto; L Arcuri; P Carosi; R Nardi; A Libonati; L Ottria; V Campanella
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

3.  In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants.

Authors:  Reiji Natsubori; Shota Fukazawa; Toyokazu Chiba; Norimasa Tanabe; Hidemichi Kihara; Hisatomo Kondo
Journal:  Int J Implant Dent       Date:  2022-04-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.