Literature DB >> 29356920

3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

Sigmar Schnutenhaus1,2, Cornelia Edelmann3, Heike Rudolph4, Jens Dreyhaupt5, Ralph G Luthardt4.   

Abstract

OBJECTIVE: The aim of this study was to investigate differences between the virtually planned and clinically achieved implant positions in completely template-guided implantations as a function of the type of edentulous space, the residual natural dentition, and the surgical implementation.
MATERIALS AND METHODS: Fifty-six patient cases with a total of 122 implants were evaluated retrospectively. The implantations were completely template-based. The data of the planned implant positions were overlaid with the actual clinical implant positions, followed by measurements of the 3D deviations in terms of coronal (xc) and apical distance, height (xh), and angulation (ang) and statistical analysis.
RESULTS: The mean xc was 1.2 mm (SD 0.7 mm); the mean xa was 1.8 mm (SD 0.9 mm), the mean xh was 0.8 mm (SD 0.7 mm); and the mean ang was 4.8° (SD 3.1). The type of edentulous space and the jaw (maxilla/mandible) had no significant effect on the results in terms of implant positions. The presence of an adjacent natural tooth at the time of implantation had a significant influence on xh (p = 0.04) and ang (p = 0.05). No significant differences were found regarding the surgical approach for any of the parameters examined.
CONCLUSION: The results of our study are in the same range as those of other studies. Template-guided implantation offers a high degree of accuracy even in the presence of different configurations of the residual dentition or different surgical approaches. A clinical benefit is therefore present, especially from a prosthetic point of view. CLINICAL RELEVANCE: The clinically achievable accuracy can be described as sufficient for further prosthetic treatment, given the intrinsic and methodological tolerances, making prosthetic rehabilitation safe and predictable.

Entities:  

Keywords:  Accuracy; CBCT; Computer-guided surgery; Dental implant; Partially edentulous jaw; Surgical template

Mesh:

Substances:

Year:  2018        PMID: 29356920     DOI: 10.1007/s00784-018-2339-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  27 in total

1.  Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.

Authors:  Chanseop Park; Ariel J Raigrodski; Jacob Rosen; Charles Spiekerman; Robert M London
Journal:  J Prosthet Dent       Date:  2009-06       Impact factor: 3.426

2.  Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study.

Authors:  Volkan Arisan; Z Cuneyt Karabuda; Tayfun Ozdemir
Journal:  J Periodontol       Date:  2010-01       Impact factor: 6.993

Review 3.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.

Authors:  David Schneider; Pascal Marquardt; Marcel Zwahlen; Ronald E Jung
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

4.  Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study.

Authors:  Sarah Katherine Turbush; Ilser Turkyilmaz
Journal:  J Prosthet Dent       Date:  2012-09       Impact factor: 3.426

5.  Accuracy of Three-Dimensional Printed Templates for Guided Implant Placement Based on Matching a Surface Scan with CBCT.

Authors:  Florian Kernen; Goran I Benic; Michael Payer; Alex Schär; Magdalena Müller-Gerbl; Andreas Filippi; Sebastian Kühl
Journal:  Clin Implant Dent Relat Res       Date:  2015-04-28       Impact factor: 3.932

6.  Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

Authors:  Alexandra Behneke; Matthias Burwinkel; Nikolaus Behneke
Journal:  Clin Oral Implants Res       Date:  2011-10-24       Impact factor: 5.977

7.  Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - a combined in vivo - in vitro technique using cone-beam CT (Part II).

Authors:  Hans-Joachim Nickenig; Manfred Wichmann; Jörg Hamel; Karl Andreas Schlegel; Stephan Eitner
Journal:  J Craniomaxillofac Surg       Date:  2009-11-24       Impact factor: 2.078

8.  Retrospective study to determine the accuracy of template-guided implant placement using a novel nonradiologic evaluation method.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph; Ralph G Luthardt
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2016-01-04

9.  Accuracy of computer-assisted implant placement with insertion templates.

Authors:  Eleni Naziri; Alexander Schramm; Frank Wilde
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2016-05-13

10.  Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study.

Authors:  Mario Beretta; Pier Paolo Poli; Carlo Maiorana
Journal:  J Periodontal Implant Sci       Date:  2014-08-28       Impact factor: 2.614

View more
  7 in total

1.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

2.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

3.  Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Authors:  Sigmar Schnutenhaus; Cornelia Edelmann; Heike Rudolph
Journal:  Int J Implant Dent       Date:  2021-04-26

4.  Geometric Reproducibility of Three-Dimensional Oral Implant Planning Based on Magnetic Resonance Imaging and Cone-Beam Computed Tomography.

Authors:  Franz Sebastian Schwindling; Sophia Boehm; Christopher Herpel; Dorothea Kronsteiner; Lorenz Vogel; Alexander Juerchott; Sabine Heiland; Martin Bendszus; Peter Rammelsberg; Tim Hilgenfeld
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

5.  Precision and trueness of computer-assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis.

Authors:  Arndt Guentsch; Hongseok An; Andrew R Dentino
Journal:  Clin Oral Implants Res       Date:  2022-02-19       Impact factor: 5.021

6.  Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study.

Authors:  Sigmar Schnutenhaus; Marie Wagner; Cornelia Edelmann; Ralph G Luthardt; Heike Rudolph
Journal:  Dent J (Basel)       Date:  2021-05-10

Review 7.  Dental Mesenchymal Stem Cell-Based Translational Regenerative Dentistry: From Artificial to Biological Replacement.

Authors:  Mona K Marei; Rania M El Backly
Journal:  Front Bioeng Biotechnol       Date:  2018-05-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.