Literature DB >> 29622801

Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

D P Laverty1, J Buglass2, A Patel3.   

Abstract

Flapless implant surgery is increasing in popularity, particularly due to advances and increased usage of cone beam computed tomography (CBCT) and dental implant treatment planning software allowing three-dimensional assessment of the implant site. It is the aim of the article to provide an overview of flapless implant surgery and CBCT guided flapless implant surgery and summarise the literature with regard to the effectiveness of this surgical technique.

Mesh:

Year:  2018        PMID: 29622801     DOI: 10.1038/sj.bdj.2018.268

Source DB:  PubMed          Journal:  Br Dent J        ISSN: 0007-0610            Impact factor:   1.626


  91 in total

1.  Short-term clinical results of Nobel Direct implants: a retrospective multicentre analysis.

Authors:  Lars Sennerby; Antonio Rocci; William Becker; Lars Jonsson; Lars-Ake Johansson; Tomas Albrektsson
Journal:  Clin Oral Implants Res       Date:  2008-03       Impact factor: 5.977

2.  Local accidents in dental implant surgery: prevention and treatment.

Authors:  Susanna Annibali; Maurizio Ripari; Gerardo La Monaca; Federica Tonoli; Maria Paola Cristalli
Journal:  Int J Periodontics Restorative Dent       Date:  2009-06       Impact factor: 1.840

Review 3.  A comparison of various methods of soft tissue management following the immediate placement of implants into extraction sockets.

Authors:  B Rosenquist
Journal:  Int J Oral Maxillofac Implants       Date:  1997 Jan-Feb       Impact factor: 2.804

4.  Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study.

Authors:  Sarah Katherine Turbush; Ilser Turkyilmaz
Journal:  J Prosthet Dent       Date:  2012-09       Impact factor: 3.426

Review 5.  Accuracy of computer-aided implant placement.

Authors:  N Van Assche; M Vercruyssen; W Coucke; W Teughels; R Jacobs; M Quirynen
Journal:  Clin Oral Implants Res       Date:  2012-10       Impact factor: 5.977

6.  Accuracy evaluation of computed tomography-derived stereolithographic surgical guides in zygomatic implant placement in human cadavers.

Authors:  Bruno R Chrcanovic; Davidson R Oliveira; Antônio L Custódio
Journal:  J Oral Implantol       Date:  2010-06-14       Impact factor: 1.779

Review 7.  Clinical outcomes of GBR procedures to correct peri-implant dehiscences and fenestrations: a systematic review.

Authors:  Matteo Chiapasco; Marco Zaniboni
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

8.  Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement.

Authors:  Alexandra Behneke; Matthias Burwinkel; Nikolaus Behneke
Journal:  Clin Oral Implants Res       Date:  2011-10-24       Impact factor: 5.977

9.  Single-stage, immediate loading, and flapless surgery.

Authors:  J Hahn
Journal:  J Oral Implantol       Date:  2000       Impact factor: 1.779

10.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients.

Authors:  Anna M Sanna; Liene Molly; Daniel van Steenberghe
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

View more
  2 in total

Review 1.  Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review.

Authors:  Gokce-Soganci Unsal; Ilser Turkyilmaz; Samantha Lakhia
Journal:  J Clin Exp Dent       Date:  2020-04-01

2.  Digital vs. Freehand Anterior Single-Tooth Implant Restoration.

Authors:  D Baldi; J Colombo; F Motta; F M Motta; A Zillio; N Scotti
Journal:  Biomed Res Int       Date:  2020-10-22       Impact factor: 3.411

  2 in total