Literature DB >> 27044419

Computer-aided flapless implant surgery and immediate loading. A technical note.

Alfonso Baruffaldi1, Pier Paolo Poli2, Andrea Baruffaldi3, Lorenzo Giberti4, Maurizio Pigozzo5, Carlo Maiorana1.   

Abstract

PURPOSE: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement.
METHODS: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software.
RESULTS: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption.
CONCLUSIONS: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.

Entities:  

Keywords:  Computer-aided surgery; Dental implants; Fixed prosthesis; Immediate loading; Surgical template; Virtual planning

Mesh:

Year:  2016        PMID: 27044419     DOI: 10.1007/s10006-016-0554-5

Source DB:  PubMed          Journal:  Oral Maxillofac Surg        ISSN: 1865-1550


  33 in total

1.  Effect of flapless surgery on pain experienced in implant placement using an image-guided system.

Authors:  Thomas Fortin; Jean Luc Bosson; Michel Isidori; Eric Blanchet
Journal:  Int J Oral Maxillofac Implants       Date:  2006 Mar-Apr       Impact factor: 2.804

Review 2.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.

Authors:  David Schneider; Pascal Marquardt; Marcel Zwahlen; Ronald E Jung
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

Review 3.  Clinical advantages of computer-guided implant placement: a systematic review.

Authors:  Margareta Hultin; Krister G Svensson; Mats Trulsson
Journal:  Clin Oral Implants Res       Date:  2012-10       Impact factor: 5.977

Review 4.  Guided surgery: accuracy and efficacy.

Authors:  Marjolein Vercruyssen; Margareta Hultin; Nele Van Assche; Krister Svensson; Ignace Naert; Marc Quirynen
Journal:  Periodontol 2000       Date:  2014-10       Impact factor: 7.589

5.  Comparison of accuracy of multiunit one-piece castings.

Authors:  B E Schiffleger; G J Ziebert; V B Dhuru; W A Brantley; K Sigaroudi
Journal:  J Prosthet Dent       Date:  1985-12       Impact factor: 3.426

6.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report.

Authors:  Daniel van Steenberghe; Ignace Naert; Matts Andersson; Izidor Brajnovic; Johan Van Cleynenbreugel; Paul Suetens
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Sep-Oct       Impact factor: 2.804

7.  The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months.

Authors:  Paulo Malo; Miguel de Araujo Nobre; Armando Lopes
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

8.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients.

Authors:  Anna M Sanna; Liene Molly; Daniel van Steenberghe
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

9.  A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template.

Authors:  Shin-Young Youk; Jee-Ho Lee; Ji-Man Park; Seong-Joo Heo; Hyun-Ki Roh; Eun-Jin Park; Im Hee Shin
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

10.  Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study.

Authors:  Mario Beretta; Pier Paolo Poli; Carlo Maiorana
Journal:  J Periodontal Implant Sci       Date:  2014-08-28       Impact factor: 2.614

View more
  2 in total

1.  Computer-guided implant placement associated with computer-aided bone regeneration in the treatment of atrophied partially edentulous alveolar ridges: A proof-of-concept study.

Authors:  Pier Paolo Poli; Anand Kumar Muktadar; Francisley Ávila Souza; Carlo Maiorana; Mario Beretta
Journal:  J Dent Sci       Date:  2020-04-03       Impact factor: 2.080

2.  Material Extrusion Based Fabrication of Surgical Implant Template and Accuracy Analysis.

Authors:  Chengyu Zhang; Yanping Yuan; Jimin Chen
Journal:  Materials (Basel)       Date:  2022-02-25       Impact factor: 3.623