Literature DB >> 31394518

MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging.

Y Petibon1, T Sun, P K Han, C Ma, G El Fakhri, J Ouyang.   

Abstract

Motion of the myocardium deteriorates the quality and quantitative accuracy of cardiac PET images. We present a method for MR-based cardiac and respiratory motion correction of cardiac PET data and evaluate its impact on estimation of activity and kinetic parameters in human subjects. Three healthy subjects underwent simultaneous dynamic 18F-FDG PET and MRI on a hybrid PET/MR scanner. A cardiorespiratory motion field was determined for each subject using navigator, tagging and golden-angle radial MR acquisitions. Acquired coincidence events were binned into cardiac and respiratory phases using electrocardiogram and list mode-driven signals, respectively. Dynamic PET images were reconstructed with MR-based motion correction (MC) and without motion correction (NMC). Parametric images of 18F-FDG consumption rates (Ki) were estimated using Patlak's method for both MC and NMC images. MC alleviated motion artifacts in PET images, resulting in improved spatial resolution, improved recovery of activity in the myocardium wall and reduced spillover from the myocardium to the left ventricle cavity. Significantly higher myocardium contrast-to-noise ratio and lower apparent wall thickness were obtained in MC versus NMC images. Likewise, parametric images of Ki calculated with MC data had improved spatial resolution as compared to those obtained with NMC. Consistent with an increase in reconstructed activity concentration in the frames used during kinetic analyses, MC led to the estimation of higher Ki values almost everywhere in the myocardium, with up to 18% increase (mean across subjects) in the septum as compared to NMC. This study shows that MR-based motion correction of cardiac PET results in improved image quality that can benefit both static and dynamic studies.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31394518      PMCID: PMC7007962          DOI: 10.1088/1361-6560/ab39c2

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  62 in total

1.  Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions.

Authors:  Catalin Loghin; Stefano Sdringola; K Lance Gould
Journal:  J Nucl Med       Date:  2004-06       Impact factor: 10.057

2.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint.

Authors:  Kai Tobias Block; Martin Uecker; Jens Frahm
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

3.  Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging.

Authors:  Arman Rahmim; Jing Tang; Habib Zaidi
Journal:  PET Clin       Date:  2012-11-26

4.  Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging.

Authors:  Yunhan Yu; Chung Chan; Tianyu Ma; Yaqiang Liu; Jean-Dominique Gallezot; Mika Naganawa; Olivia J Kelada; Mary Germino; Albert J Sinusas; Richard E Carson; Chi Liu
Journal:  J Nucl Med       Date:  2016-02-23       Impact factor: 10.057

5.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

6.  Motion frozen (18)F-FDG cardiac PET.

Authors:  Ludovic Le Meunier; Piotr J Slomka; Damini Dey; Amit Ramesh; Louis E J Thomson; Sean W Hayes; John D Friedman; Victor Cheng; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2010-12-16       Impact factor: 5.952

7.  Correction of hysteretic respiratory motion in SPECT myocardial perfusion imaging: Simulation and patient studies.

Authors:  Paul K R Dasari; Arda Könik; P Hendrik Pretorius; Karen L Johnson; William P Segars; Mohammed S Shazeeb; Michael A King
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

8.  Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging.

Authors:  Jing Tang; Xinhui Wang; Xiangzhen Gao; W Paul Segars; Martin A Lodge; Arman Rahmim
Journal:  Phys Med Biol       Date:  2017-03-02       Impact factor: 3.609

9.  Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation.

Authors:  W J Rogers; E P Shapiro; J L Weiss; M B Buchalter; F E Rademakers; M L Weisfeldt; E A Zerhouni
Journal:  Circulation       Date:  1991-08       Impact factor: 29.690

10.  Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging.

Authors:  Yoann Petibon; Chuan Huang; Jinsong Ouyang; Timothy G Reese; Quanzheng Li; Aleksandra Syrkina; Yen-Lin Chen; Georges El Fakhri
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

View more
  9 in total

1.  18F-FDG PET/CT in diagnostic and prognostic evaluation of patients with cardiac masses: a retrospective study.

Authors:  Chunxia Qin; Fuqiang Shao; Fan Hu; Wenyu Song; Yangmeihui Song; Jinxia Guo; Xiaoli Lan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-12-05       Impact factor: 9.236

2.  Multiparametric Cardiac 18F-FDG PET in Humans: Kinetic Model Selection and Identifiability Analysis.

Authors:  Yang Zuo; Ramsey D Badawi; Cameron C Foster; Thomas Smith; Javier E López; Guobao Wang
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-10-15

3.  Motion correction for PET data using subspace-based real-time MR imaging in simultaneous PET/MR.

Authors:  Thibault Marin; Yanis Djebra; Paul K Han; Yanis Chemli; Isabelle Bloch; Georges El Fakhri; Jinsong Ouyang; Yoann Petibon; Chao Ma
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 3.609

Review 4.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

5.  Quantitative PET in the 2020s: a roadmap.

Authors:  Steven R Meikle; Vesna Sossi; Emilie Roncali; Simon R Cherry; Richard Banati; David Mankoff; Terry Jones; Michelle James; Julie Sutcliffe; Jinsong Ouyang; Yoann Petibon; Chao Ma; Georges El Fakhri; Suleman Surti; Joel S Karp; Ramsey D Badawi; Taiga Yamaya; Go Akamatsu; Georg Schramm; Ahmadreza Rezaei; Johan Nuyts; Roger Fulton; André Kyme; Cristina Lois; Hasan Sari; Julie Price; Ronald Boellaard; Robert Jeraj; Dale L Bailey; Enid Eslick; Kathy P Willowson; Joyita Dutta
Journal:  Phys Med Biol       Date:  2021-03-12       Impact factor: 4.174

6.  Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET.

Authors:  Tao Sun; Yaping Wu; Wei Wei; Fangfang Fu; Nan Meng; Hongzhao Chen; Xiaochen Li; Yan Bai; Zhenguo Wang; Jie Ding; Debin Hu; Chaojie Chen; Zhanli Hu; Dong Liang; Xin Liu; Hairong Zheng; Yongfeng Yang; Yun Zhou; Meiyun Wang
Journal:  EJNMMI Phys       Date:  2022-09-14

Review 7.  Hybrid PET/MR imaging in myocardial inflammation post-myocardial infarction.

Authors:  B Wilk; G Wisenberg; R Dharmakumar; J D Thiessen; D E Goldhawk; F S Prato
Journal:  J Nucl Cardiol       Date:  2019-12-03       Impact factor: 5.952

8.  Design and system evaluation of a dual-panel portable PET (DP-PET).

Authors:  Tianyi Zeng; Jiaxu Zheng; Xinyuan Xia; Xin Chen; Beien Wang; Shuangyue Zhang; Adam Chandler; Tuoyu Cao; Lingzhi Hu; Qun Chen; Xu Chu
Journal:  EJNMMI Phys       Date:  2021-06-12

9.  Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning.

Authors:  Luyao Shi; Yihuan Lu; Nicha Dvornek; Christopher A Weyman; Edward J Miller; Albert J Sinusas; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.