Literature DB >> 28576170

Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

Yothin Rakvongthai1, Georges El Fakhri2.   

Abstract

Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cardiac motion; MR-based motion correction; PET-MR; Respiratory motion

Mesh:

Substances:

Year:  2017        PMID: 28576170      PMCID: PMC6452624          DOI: 10.1016/j.cpet.2017.02.004

Source DB:  PubMed          Journal:  PET Clin        ISSN: 1556-8598


  36 in total

1.  A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1999-04       Impact factor: 10.048

2.  Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results.

Authors:  Luc Boucher; Serge Rodrigue; Roger Lecomte; François Bénard
Journal:  J Nucl Med       Date:  2004-02       Impact factor: 10.057

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  High-resolution PET detector design: modelling components of intrinsic spatial resolution.

Authors:  Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-21       Impact factor: 3.609

Review 5.  PET/CT imaging artifacts.

Authors:  Waheeda Sureshbabu; Osama Mawlawi
Journal:  J Nucl Med Technol       Date:  2005-09

6.  Lung motion correction on respiratory gated 3-D PET/CT images.

Authors:  Mohammad Dawood; Norbert Lang; Xiaoyi Jiang; Klaus P Schäfers
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

7.  A motion-incorporated reconstruction method for gated PET studies.

Authors:  Feng Qiao; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  Phys Med Biol       Date:  2006-07-20       Impact factor: 3.609

8.  Four-dimensional (4D) PET/CT imaging of the thorax.

Authors:  S A Nehmeh; Y E Erdi; T Pan; A Pevsner; K E Rosenzweig; E Yorke; G S Mageras; H Schoder; Phil Vernon; O Squire; H Mostafavi; S M Larson; J L Humm
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

9.  Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source.

Authors:  Dimitri Papathanassiou; Stéphanie Becker; Roland Amir; Benoît Menéroux; Jean-Claude Liehn
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-08-31       Impact factor: 9.236

10.  Effect of respiratory gating on quantifying PET images of lung cancer.

Authors:  Sadek A Nehmeh; Yusuf E Erdi; Clifton C Ling; Kenneth E Rosenzweig; Heiko Schoder; Steve M Larson; Homer A Macapinlac; Olivia D Squire; John L Humm
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

View more
  4 in total

1.  MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging.

Authors:  Y Petibon; T Sun; P K Han; C Ma; G El Fakhri; J Ouyang
Journal:  Phys Med Biol       Date:  2019-10-04       Impact factor: 3.609

2.  Performance evaluation of dedicated brain PET scanner with motion correction system.

Authors:  Yuya Onishi; Takashi Isobe; Masanori Ito; Fumio Hashimoto; Tomohide Omura; Etsuji Yoshikawa
Journal:  Ann Nucl Med       Date:  2022-06-13       Impact factor: 2.258

3.  Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling.

Authors:  Philip M Robson; MariaGiovanna Trivieri; Nicolas A Karakatsanis; Maria Padilla; Ronan Abgral; Marc R Dweck; Jason C Kovacic; Zahi A Fayad
Journal:  Phys Med Biol       Date:  2018-11-14       Impact factor: 3.609

4.  Quantitative PET in the 2020s: a roadmap.

Authors:  Steven R Meikle; Vesna Sossi; Emilie Roncali; Simon R Cherry; Richard Banati; David Mankoff; Terry Jones; Michelle James; Julie Sutcliffe; Jinsong Ouyang; Yoann Petibon; Chao Ma; Georges El Fakhri; Suleman Surti; Joel S Karp; Ramsey D Badawi; Taiga Yamaya; Go Akamatsu; Georg Schramm; Ahmadreza Rezaei; Johan Nuyts; Roger Fulton; André Kyme; Cristina Lois; Hasan Sari; Julie Price; Ronald Boellaard; Robert Jeraj; Dale L Bailey; Enid Eslick; Kathy P Willowson; Joyita Dutta
Journal:  Phys Med Biol       Date:  2021-03-12       Impact factor: 4.174

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.