Literature DB >> 17555235

Slit design for efficient and accurate MTF measurement at megavoltage x-ray energies.

Amit Sawant1, Larry Antonuk, Youcef El-Mohri.   

Abstract

Empirical determination of the modulation transfer function (MTF) for analog and digital mega-voltage x-ray imagers is a challenging task. The most common method used to determine MTF at megavoltage x-ray energies employs a long, narrow slit formed by two parallel, metal blocks in order to form a "slit beam." In this work, a detailed overview of some of the important considerations of slit design is presented. Based on these considerations, a novel, compact slit, using 19 cm thick tungsten blocks, was designed. The prototype slit was configured to attach to the accessory slot of the gantry of a linear accelerator, which greatly simplified the measurement process. Measurements were performed to determine the presampling MTF at 6 MV for an indirect detection active matrix flat panel imager prototype previously developed for megavoltage imaging applications. In addition, the effects of two important slit design parameters, material type and thickness, on the accuracy of MTF determination were investigated via a Monte Carlo-based theoretical study. Empirically determined MTFs obtained from the prototype slit closely match those from an earlier, less compact slit design based on 40 cm thick steel blocks. The results of the Monte Carlo-based theoretical studies indicate that the prototype slit achieves close-to-ideal performance in terms of accurately determining the MTF by virtue of practically 100% beam attenuation in regions other than the slit gap. Furthermore, the theoretical results suggest that it may be possible to achieve even further reductions in slit thickness without compromising measurement accuracy.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17555235     DOI: 10.1118/1.2717405

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

2.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

3.  A novel EPID design for enhanced contrast and detective quantum efficiency.

Authors:  Joerg Rottmann; Daniel Morf; Rony Fueglistaller; George Zentai; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

4.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

5.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.