Megavoltage cone-beam CT: system description and clinical applications.

Olivier Morin1, Amy Gillis, Josephine Chen, Michèle Aubin, M Kara Bucci, Mack Roach, Jean Pouliot.   

Abstract

In this article, we describe a clinical mega-voltage cone-beam computed tomography (MV CBCT) system, present the image acquisition and patient setup procedure, discuss the positioning accuracy and image quality, and illustrate its potential use for image-guided radiation therapy (IGRT) through selected clinical examples. The MV CBCT system consists of a standard linear accelerator equipped with an amorphous-silicon flat panel electronic portal-imaging device adapted for mega-electron volt (MeV) photons. An integrated computer workspace provides automated acquisition of projection images, image reconstruction, CT to CBCT image registration, and couch shift calculation. The system demonstrates submillimeter localization precision and sufficient soft-tissue resolution to visualize structures such as the prostate. In our clinic, we have used the MV CBCT system to detect nonrigid spinal cord distortions, monitor tumor growth and shrinkage, and locate and position stationary tumors in the lung. MV CBCT has also greatly improved the delineation of structures in CT images that suffer from metal artifacts. MV CBCT has undergone significant development in the last few years. Current image quality has already proven sufficient for many IGRT applications. Moreover, we expect the range of clinical applications for MV CBCT to grow as imaging technology continues to improve.

Entities:  

Mesh:

Year:  2006        PMID: 16551529     DOI: 10.1016/j.meddos.2005.12.009

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  52 in total

1.  Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

Authors:  H K Looe; Y Uphoff; D Harder; B Poppe; K C Willborn
Journal:  Strahlenther Onkol       Date:  2012-01-12       Impact factor: 3.621

2.  Super-resolution imaging in a multiple layer EPID.

Authors:  Haijian Chen; Joerg Rottmann; Stephen Sf Yip; Daniel Morf; Rony Füglistaller; Josh Star-Lack; George Zentai; Ross Berbeco
Journal:  Biomed Phys Eng Express       Date:  2017-02-21

3.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

5.  Three-D imaging of dental alveolar bone change after fixed orthodontic treatment in patients with periodontitis.

Authors:  Zhi-Gui Ma; Chi Yang; Bing Fang; Yun-Hui Xia; Li-Xia Mao; Yi-Miao Feng
Journal:  Int J Clin Exp Med       Date:  2015-02-15

6.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

7.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

8.  Monitoring external beam radiotherapy using real-time beam visualization.

Authors:  Cesare H Jenkins; Dominik J Naczynski; Shu-Jung S Yu; Lei Xing
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

9.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

10.  Use of kilovoltage X-ray volume imaging in patient dose calculation for head-and-neck and partial brain radiation therapy.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Xuejun Ma; Zhen Zhang
Journal:  Radiat Oncol       Date:  2010-04-19       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.