A bench-top megavoltage fan-beam CT using CdWO4-photodiode detectors. II. Image performance evaluation.

T T Monajemi1, D Tu, B G Fallone, S Rathee.   

Abstract

Megavoltage computed tomography (MVCT) is a potential imaging tool for positioning and dose delivery verification during image guided radiotherapy. The problem with many MVCT detectors, however, is their low detective quantum efficiency (DQE) which leads to poor low contrast resolution (LCR) and high image noise. This makes separating the tumors from the soft tissue background difficult. This manuscript describes the imaging performance of our bench-top MVCT scanner that uses an 80-element detector array consisting of CdWO4-photodiode elements with a DQE of 19% in 6 MV and 26% in Co60 beams [T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modelling scintillator-photodiodes as detectors for megavoltage CT," Med. Phys. 31, 1225-1234 (2004)] at zero frequency. The imaging experiments presented were carried out mainly in a Co60 teletherapy unit, while the beam hardening characteristics of the system were also presented for a 6 MV beam. During image evaluation, persistent ring artifacts, caused by air gaps at the ends of the eight-element detector blocks, were removed by using a calibration procedure. The measured contrast of a low contrast target with a 20 mm diameter was determined to be independent of dose, between 2.1 and 17 cGy. The measured LCR of a target with a nominal contrast of 2.8% was reduced from 2.3% to 1.2% when the contrast target diameter was reduced from 15 to 5 mm, using 17 cGy for imaging. The signal to noise ratio of this system is shown to be proportional to the square root of dose. Most importantly, a low contrast target with a diameter of 6 mm and a nominal contrast level of 1.5% is resolved with a radiation dose of 2.1 cGy in the Co60 beam. The spatial resolution in the Co60 beam is limited to one line pair per centimeter mainly due to the size of the Co60 source.

Entities:  

Mesh:

Year:  2006        PMID: 16696486     DOI: 10.1118/1.2181291

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging.

Authors:  Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Yi Wang; Hong Du; Amit Sawant; Zhong Su; Jin Yamamoto
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

4.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

5.  Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Youcef El-Mohri; Larry E Antonuk; Qihua Zhao
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

6.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

7.  Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Richard B Choroszucha; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

8.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

9.  Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

Authors:  Jian Liu; Yuan Xu; Aram Teymurazyan; Zisis Papandreou; Geordi Pang
Journal:  Med Phys       Date:  2019-11-04       Impact factor: 4.071

10.  The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance.

Authors:  L John Schreiner; Chandra P Joshi; Johnson Darko; Andrew Kerr; Greg Salomons; Sandeep Dhanesar
Journal:  J Med Phys       Date:  2009-07
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.