Literature DB >> 24317331

Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

Tolga İnal1, Gökçe Ataç.   

Abstract

PURPOSE: We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey.
MATERIALS AND METHODS: Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency.
RESULTS: The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study.
CONCLUSION: This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

Entities:  

Mesh:

Year:  2014        PMID: 24317331      PMCID: PMC4463244          DOI: 10.5152/dir.2013.12122

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  8 in total

1.  Transition from screen-film to digital radiography: evolution of patient radiation doses at projection radiography.

Authors:  Eliseo Vaño; José Miguel Fernández; José Ignacio Ten; Carlos Prieto; Luciano González; Ricardo Rodríguez; Hugo de las Heras
Journal:  Radiology       Date:  2007-03-13       Impact factor: 11.105

2.  A new Diamentor for measuring kerma-area product and air-kerma simultaneously.

Authors:  H Gfirtner; F E Stieve; J Wild
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

3.  Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.

Authors:  D A Johnston; P C Brennan
Journal:  Br J Radiol       Date:  2000-04       Impact factor: 3.039

Review 4.  Patient dosimetry measurement methods.

Authors:  K Faulkner; D A Broadhead; R M Harrison
Journal:  Appl Radiat Isot       Date:  1999-01       Impact factor: 1.513

5.  Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology.

Authors:  D Bor; T Sancak; T Olgar; Y Elcim; A Adanali; U Sanlidilek; S Akyar
Journal:  Br J Radiol       Date:  2004-04       Impact factor: 3.039

6.  X-ray imaging of the chest in Switzerland in 1998: a nationwide survey.

Authors:  A Aroua; R Bize; I Buchillier-Decka; J-P Vader; J-F Valley; P Schnyder
Journal:  Eur Radiol       Date:  2002-10-24       Impact factor: 5.315

7.  Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures.

Authors:  B J McParland
Journal:  Br J Radiol       Date:  1998-12       Impact factor: 3.039

8.  Optimization of dose and image quality for computed radiography and digital radiography.

Authors:  John E Aldrich; Emerenciana Duran; Pat Dunlop; John R Mayo
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

  8 in total
  1 in total

1.  Local diagnostic reference levels for routine chest X-ray examinations at a public sector hospital in central South Africa.

Authors:  Maurice Junda; Henra Muller; Hesta Friedrich-Nel
Journal:  Health SA       Date:  2021-08-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.