Literature DB >> 15107322

Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology.

D Bor1, T Sancak, T Olgar, Y Elcim, A Adanali, U Sanlidilek, S Akyar.   

Abstract

In this study, measurements of dose-area product (DAP) and entrance dose were carried out simultaneously in a sample of 162 adult patients who underwent different interventional examinations. Effective doses for each measurement technique were estimated using the conversion factors that have been determined for specific X-ray views in a mathematical phantom. Exposure conditions used in clinical practice never match these theoretical models exactly, and deviations from the assumed standard conditions cause uncertainties in effective dose estimations. Higher effective dose values are found if the air kerma results are used rather than DAP readings, both for patient and Rando phantom studies. Comparison of DAP, fluoroscopy times and skin doses were made with published data. DAP measurement for the effective dose calculation and thermoluminescent dosimeter for the skin dose estimates are found to be the most reliable methods for patient dosimetry.

Entities:  

Mesh:

Year:  2004        PMID: 15107322     DOI: 10.1259/bjr/29942833

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  16 in total

1.  Risk of deterministic effects during endovascular aortic stent graft implantation.

Authors:  D Kuhelj; U Zdesar; V Jevtic; D Skrk; G Omahen; D Zontar; M Surlan; M Glusic; P Popovic; I J Kocijancic; V Salapura
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

2.  The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation.

Authors:  Satoshi Fujita; Eitaro Fujii; Yoshihiko Kagawa; Katsuhiro Inoue; Tsuyoshi Yamada; Masaaki Ito
Journal:  Heart Vessels       Date:  2018-05-07       Impact factor: 2.037

3.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

4.  Effective-dose estimation in interventional radiological procedures.

Authors:  Maria D Falco; Salvatore Masala; Matteo Stefanini; Paolo Bagalà; Daniele Morosetti; Eros Calabria; Alessia Tonnetti; Gianluca Verona-Rinati
Journal:  Radiol Phys Technol       Date:  2018-03-08

5.  Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

Authors:  Tolga İnal; Gökçe Ataç
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

6.  Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: experience at a single center.

Authors:  Chang Woo Chun; Bum-Soo Kim; Cheol Hyoun Lee; Yon Kwon Ihn; Yong-Sam Shin
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

7.  The contribution of interventional cardiology procedures to the population radiation dose in a 'health-care level I' representative region.

Authors:  Andrea Peruzzo Cornetto; Stefania Aimonetto; Francesco Pisano; Marcello Giudice; Marco Sicuro; Teodoro Meloni; Santi Tofani
Journal:  Radiat Prot Dosimetry       Date:  2015-05-25       Impact factor: 0.972

8.  Impact of latest generation cardiac interventional X-ray equipment on patient image quality and radiation dose for trans-catheter aortic valve implantations.

Authors:  Amber J Gislason-Lee; Claire Keeble; Christoper J Malkin; Daniel Egleston; Josephine Bexon; Stephen M Kengyelics; Daniel Blackman; Andrew G Davies
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

9.  Evaluation of exposure dose to patients undergoing catheter ablation procedures--a phantom study.

Authors:  S Seguchi; T Aoyama; S Koyama; C Kawaura; K Fujii
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

10.  Evaluation of radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Thailand.

Authors:  J Urairat; S Asavaphatiboon; S Singhara Na Ayuthaya; N Pongnapang
Journal:  Biomed Imaging Interv J       Date:  2011-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.