| Literature DB >> 34522394 |
Maurice Junda1, Henra Muller1, Hesta Friedrich-Nel1.
Abstract
BACKGROUND: Dose optimisation is a radiation protection guideline recommended by the International Commission on Radiological Protection (ICRP) for adherence to the 'as low as reasonably achievable' (ALARA) principle. Diagnostic reference levels (DRLs) are used to optimise patients' radiation protection for diagnostic and interventional procedures and are particularly useful for frequently performed examinations such as chest X-rays. AIM: To establish the local diagnostic reference levels (LDRLs) for routine chest X-rays.Entities:
Keywords: ALARA; DRLs; chest X-ray; diagnostic reference levels; digital radiography; entrance surface air kerma
Year: 2021 PMID: 34522394 PMCID: PMC8424719 DOI: 10.4102/hsag.v26i0.1622
Source DB: PubMed Journal: Health SA ISSN: 1025-9848
Specifications of the X-ray machines at the research site.
| Specifications | Room 1 | Room 2 | Room 3 |
|---|---|---|---|
| Make | Shimadzu | Siemens | Philips |
| Model | UD 150 V-40 | Polydoros IT | Digital Diagnost TH |
| Total filtration | 2.5 mm Al at 70 kV | 2.5 mm Al at 70 kV | 2.5 mm Al at 70 kV |
| Exposure setting | Manual | Manual/automatic | Manual/automatic |
| Grid ratio | - | 17:1 | 12:1 |
kV, kilovoltage; mm, millimetre; –, no data available.
Patients’ weight and thickness for posteroanterior and lateral chest projections (n = 60 patients).
| Variable | Posteroanterior chest projections | Lateral chest projections | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | Median | Min | Max | Mean | Median | Min | Max | |
| Weight (kg) | 69.6 | 70.5 | 60.0 | 80.0 | 69.6 | 70.5 | 60.0 | 80.0 |
| Thickness (cm) | 23.5 | 23.0 | 18.0 | 31.0 | 29.2 | 30.0 | 18.0 | 37.0 |
Min, minimum; Max, maximum.
Radiographic parameters for posteroanterior and lateral chest projections at the research site (n = 60 patients).
| Variable | Posteroanterior chest projections | Lateral chest projections | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | Median | Min | Max | Mean | Median | Min | Max | |
| mAs | 3.6 | 4.0 | 1.0 | 5.6 | 9.7 | 9.7 | 3.4 | 19.8 |
| kVp | 113.7 | 112.5 | 102.0 | 125.0 | 117.0 | 117.0 | 103.0 | 125.0 |
| SID | 178.5 | 180.0 | 150.0 | 180.0 | 178.5 | 180.0 | 150.0 | 180.0 |
Min, minimum; Max, maximum; mAs, milliampere-second; kVp, kilovoltage peak; SID, source image distance.
Entrance skin air kerma (mGy) values for posteroanterior and lateral chest projections of computed radiography and digital radiography (flat panel detector) systems.
| Type of radiography | Posteroanterior chest projections | Lateral chest projections | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | Median | Min | Max | Mean | Median | Min | Max | |
| CR ( | 0.2 | 0.2 | 0.2 | 0.4 | 0.6 | 0.6 | 0.4 | 0.9 |
| DR (FPD) ( | 0.1 | 0.1 | 0.1 | 0.3 | 0.6 | 0.5 | 0.2 | 1.4 |
Min, minimum; Max, maximum; CR, computed radiography; DR (FPD), digital radiography (flat panel detector).
Comparison of the entrance skin air kerma (mGy) values of this study to other international entrance skin air kerma values
| Study and country | Projection | |
|---|---|---|
| Chest PA | Chest LAT | |
|
| ||
| Mean | 0.10; 0.09 | 0.23; 0.19 |
| Minimum | 0.05; 0.05 | 0.12; 0.07 |
| Maximum | 0.20; 0.15 | 0.44; 0.26 |
|
| ||
| Mean | 0.12 | 0.48 |
| Minimum | 0.02 | 0.22 |
| Maximum | 1.1 | 1.26 |
|
| ||
| Mean | 0.33 | 0.73 |
| Minimum | - | - |
| Maximum | - | - |
|
| ||
| Mean | 0.6 | 0.85 |
| Minimum | 0.13 | 0.25 |
| Maximum | 1.12 | 1.98 |
|
| ||
| Mean | 0.12 | 0.66 |
| Minimum | - | - |
| Maximum | - | - |
|
| ||
| Mean | 0.49 | - |
| Minimum | 0.07 | - |
| Maximum | 2.35 | - |
|
| ||
| Mean | 1.0 | 1.7 |
| Minimum | 0.2 | 0.3 |
| Maximum | 3.3 | 4.3 |
|
| ||
| Mean | 0.14 | 0.49 |
| Minimum | - | - |
| Maximum | - | - |
|
| ||
| Mean | 0.2 | 0.6 |
| Minimum | 0.1 | 0.2 |
| Maximum | 0.4 | 1.4 |
PA, posteroanterior; LAT, lateral.
, In this study, separate values were provided for two examination rooms.
, In this study, entrance skin dose (ESD) values were reported, not entrance skin air kerma (ESAK).
Comparison of local diagnostic reference levels (mGy) of this study to internationally recommended and previously published diagnostic reference levels.
| Study and country | Projection | |
|---|---|---|
| Chest PA | Chest LAT | |
| IAEA ( | 0.30 | 1.50 |
| Nyathi et al. ( | 0.10 | 0.20 |
| Hart et al. ( | 0.15 | 0.54 |
| Baş Mor et al. ( | 0.35 | 0.78 |
| European Commission ( | 0.30 | 1.50 |
| Mohsenzadeh et al. ( | 0.63 | 1.11 |
| Ahmed et al. ( | 0.60 | – |
| Hoseini Motlagh et al. ( | 1.40 | 2.10 |
| Suliman ( | 0.20 | 0.60 |
| This study (2020); South Africa | 0.30 | 0.80 |
PA, posteroanterior; LAT, lateral; IAEA, International Atomic Energy Agency.
, Most commonly used value.