PURPOSE: To retrospectively evaluate patient radiation doses in projection radiography after the transition to computed radiography (CR) in the authors' hospital.
MATERIALS AND METHODS: The hospital's ethical committee approved the study and waived informed consent. In 2001, a dose reduction initiative was implemented, which involved collecting radiographic parameters, calculating patient entrance doses, and monitoring changes with an online computer, and a training program for radiographers was conducted. A database with 204 660 patient dose values was used to compute changes in patient doses over time. Sample sizes ranged from 1800 to 23 000 examinations. Doses were compared with European and American reference values. Kruskal-Wallis and Mann-Whitney tests were used for statistical analysis.
RESULTS: Median values for patient entrance doses increased 40%-103% after implementation of CR. Initial increases were corrected during the 1st year, and additional dose decreases were achieved after the dose reduction initiative was launched. At present, doses range between 15% and 38% of the European diagnostic reference levels established for screen-film radiography and between 28% and 41% of the reference values recommended by the American Association of Physicists in Medicine, representing an effective 20%-50% reduction in the initial values for CR.
CONCLUSION: Though patient doses can increase considerably during the transition from conventional screen-film radiography to CR, dose management programs, including specific training of radiographers and patient dose audits, allow for reductions of the previous values.

Entities:  

Mesh:

Year:  2007        PMID: 17356174     DOI: 10.1148/radiol.2432050930

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Quality assurance: a comparison study of radiographic exposure for neonatal chest radiographs at 4 academic hospitals.

Authors:  Mervyn D Cohen; Richard Markowitz; Jeanne Hill; Walter Huda; Paul Babyn; Bruce Apgar
Journal:  Pediatr Radiol       Date:  2011-11-06

2.  Optimal beam quality for chest flat panel detector system: realistic phantom study.

Authors:  Chie Kuwahara; Takatoshi Aoki; Nobuhiro Oda; Jun Kawabata; Koichiro Sugimoto; Michiko Kobayashi; Masami Fujii; Yukunori Korogi
Journal:  Eur Radiol       Date:  2019-02-08       Impact factor: 5.315

3.  [Dose reduction and adequate image quality in digital radiography: a contradiction?].

Authors:  S Pötter-Lang; M Dünkelmeyer; M Uffmann
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

Review 4.  European trends in radiology: investigating factors affecting the number of examinations and the effective dose.

Authors:  Hamidreza Masjedi; Mohammad Hosein Zare; Neda Keshavarz Siahpoush; Seid Kazem Razavi-Ratki; Fatemeh Alavi; Masoud Shabani
Journal:  Radiol Med       Date:  2019-12-16       Impact factor: 3.469

5.  Quality assurance: using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates.

Authors:  Mervyn D Cohen; Matt L Cooper; Kelly Piersall; Bruce K Apgar
Journal:  Pediatr Radiol       Date:  2010-12-30

6.  Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

Authors:  Tolga İnal; Gökçe Ataç
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

7.  Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement.

Authors:  Ursula Mothiram; Patrick C Brennan; John Robinson; Sarah J Lewis; Bernadette Moran
Journal:  J Med Radiat Sci       Date:  2013-11-20

8.  The Reliability of Two- and Three-Dimensional Cephalometric Measurements: A CBCT Study.

Authors:  Chenshuang Li; Hellen Teixeira; Nipul Tanna; Zhong Zheng; Stephanie Hsiang Yi Chen; Min Zou; Chun-Hsi Chung
Journal:  Diagnostics (Basel)       Date:  2021-12-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.