Determination and verification of the x-ray spectrum of a CT scanner.

Ahmad Ibrahim Hassan1,2, Martin Skalej1, Helmut Schlattl3, Christoph Hoeschen2.   

Abstract

The accuracy of Monte Carlo (MC) simulations in estimating the computed tomography radiation dose is highly dependent on the proprietary x-ray source information. To address this, this study develops a method to precisely estimate the x-ray spectrum and bowtie (BT) filter thickness of the x-ray source based on physical measurements and calculations. The static x-ray source of the CT localizer radiograph was assessed to measure the total filtration at the isocenter for the x-ray spectrum characterization and the BT profile (air-kerma values as a function of fan angle). With these values, the utilized BT filter in the localizer radiograph was assessed by integrating the measured air kerma in a full 360-deg cycle. The consistency observed between the integrated BT filter profiles and the directly measured profiles pointed to the similarity in the utilized BT filter in terms of thickness and material between the static and rotating x-ray geometries. Subsequently, the measured air kerma was used to calculate the BT filter thickness and was verified using MC simulations by comparing the calculated and measured air-kerma values, where a very good agreement was observed. This would allow a more accurate computed tomography simulation and facilitate the estimation of the dose delivered to the patients.

Entities:  

Keywords:  CT localizer radiograph; Monte Carlo simulations; bowtie filter; multidetector CT; radiation dose; x-ray spectrum

Year:  2018        PMID: 29430476      PMCID: PMC5802155          DOI: 10.1117/1.JMI.5.1.013506

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  41 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners.

Authors:  Adam C Turner; Maria Zankl; John J DeMarco; Chris H Cagnon; Di Zhang; Erin Angel; Dianna D Cody; Donna M Stevens; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

Authors:  Xinhua Li; Jim Q Shi; Da Zhang; Sarabjeet Singh; Atul Padole; Alexi Otrakji; Mannudeep K Kalra; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

4.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography.

Authors:  Duncan R Coles; Mary A Smail; Ian S Negus; Peter Wilde; Martin Oberhoff; Karl R Karsch; Andreas Baumbach
Journal:  J Am Coll Cardiol       Date:  2006-04-19       Impact factor: 24.094

6.  Direct and fast measurement of CT beam filter profiles with simultaneous geometrical calibration.

Authors:  Kai Yang; Xinhua Li; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

7.  GMctdospp: Description and validation of a CT dose calculation system.

Authors:  Ralph Schmidt; Jörg Wulff; Klemens Zink
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

8.  Patient dose reduction in CT examinations by optimising scanogram acquisition.

Authors:  K Perisinakis; J Damilakis; A Voloudaki; A Papadakis; N Gourtsoyiannis
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

9.  Dose to radiosensitive organs during routine chest CT: effects of tube current modulation.

Authors:  Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; John J DeMarco; Christopher H Cagnon; Jonathan G Goldin; Cynthia H McCollough; Andrew N Primak; Dianna D Cody; Donna M Stevens; Michael F McNitt-Gray
Journal:  AJR Am J Roentgenol       Date:  2009-11       Impact factor: 3.959

10.  Assessment of patient dose from CT localizer radiographs.

Authors:  Bernhard Schmidt; Natalia Saltybaeva; Daniel Kolditz; Willi A Kalender
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more
  1 in total

1.  A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study.

Authors:  Patrizio Barca; Fabio Paolicchi; Giacomo Aringhieri; Federica Palmas; Daniela Marfisi; Maria Evelina Fantacci; Davide Caramella; Marco Giannelli
Journal:  PLoS One       Date:  2021-01-14       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.