Literature DB >> 3626996

Monte Carlo evaluation of kerma at a point for photon transport problems.

J F Williamson.   

Abstract

Estimation of collision kerma at a geometric point arising from scattered photons is a potentially important application of Monte Carlo simulation, especially in the presence of steep flux gradients. We examine the usual method of extracting point-kerma estimates from randomly generated photon trajectories which consists of tallying the energy lost by photon collisions occurring in the vicinity of the point of interest. Several other methods derived from the equivalence of track length per unit volume and flux are evaluated as to accuracy and efficiency. Finally, a next-flight estimator is discussed in which the expected contribution of each simulated photon collision to kerma at the point of interest is calculated regardless of proximity of the collision to the point. All of these techniques are shown to involve a trade-off between statistical precision and spatial resolution: increasing the number of contributing collisions requires averaging kerma over a larger volume. Based upon both analytic models and realistic Monte Carlo simulations, use of next-flight and track-length estimators is shown to improve simulation efficiencies by factors of 2 to 20 compared to analog scoring. Practical guidelines as to choice of estimator and successful implementation are presented.

Mesh:

Year:  1987        PMID: 3626996     DOI: 10.1118/1.596069

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Monte Carlo calculation of patient organ doses from computed tomography.

Authors:  Takeshi Oono; Fujio Araki; Shoya Tsuduki; Keiichi Kawasaki
Journal:  Radiol Phys Technol       Date:  2013-11-30

3.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories.

Authors:  Pooyan Sahbaee; W Paul Segars; Ehsan Samei
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

5.  Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

6.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

Review 7.  Air kerma and absorbed dose standards for reference dosimetry in brachytherapy.

Authors:  T Sander
Journal:  Br J Radiol       Date:  2014-07-07       Impact factor: 3.039

8.  Estimating statistical uncertainty of Monte Carlo efficiency-gain in the context of a correlated sampling Monte Carlo code for brachytherapy treatment planning with non-normal dose distribution.

Authors:  Nitai D Mukhopadhyay; Andrew J Sampson; Daniel Deniz; Gudrun Alm Carlsson; Jeffrey Williamson; Alexandr Malusek
Journal:  Appl Radiat Isot       Date:  2011-09-29       Impact factor: 1.513

9.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

10.  Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

Authors:  Javier Vijande; Domingo Granero; Jose Perez-Calatayud; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2012-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.