Literature DB >> 24162155

Digital templating in total knee and hip replacement: an analysis of planning accuracy.

Bettina Kniesel1, Lukas Konstantinidis, Anja Hirschmüller, Norbert Südkamp, Peter Helwig.   

Abstract

PURPOSE: The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted.
METHODS: Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery.
RESULTS: The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups.
CONCLUSION: In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.

Entities:  

Mesh:

Year:  2013        PMID: 24162155      PMCID: PMC3971267          DOI: 10.1007/s00264-013-2157-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs.

Authors:  M J Oddy; M J Jones; C J Pendegrass; J R Pilling; J A Wimhurst
Journal:  J Bone Joint Surg Br       Date:  2006-05

2.  Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty.

Authors:  Christopher O Bayne; Michael Krosin; Thomas C Barber
Journal:  J Arthroplasty       Date:  2008-04-18       Impact factor: 4.757

3.  The reliability and accuracy of digital templating in total knee replacement.

Authors:  R W Trickett; P Hodgson; M C Forster; A Robertson
Journal:  J Bone Joint Surg Br       Date:  2009-07

4.  Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software.

Authors:  S P White; J Bainbridge; E J Smith
Journal:  Ann R Coll Surg Engl       Date:  2008-10       Impact factor: 1.891

5.  The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.

Authors:  Florian Schmidutz; Arnd Steinbrück; Lorenz Wanke-Jellinek; Matthias Pietschmann; Volkmar Jansson; Andreas Fottner
Journal:  Int Orthop       Date:  2012-04-04       Impact factor: 3.075

6.  The utility of digital templating in Total Hip Arthroplasty with Crowe type II and III dysplastic hips.

Authors:  Xin Zhao; Zhen-An Zhu; Jie Zhao; Mao-Qiang Li; Gang Wang; De-Gang Yu; Bo Yu
Journal:  Int Orthop       Date:  2010-03-14       Impact factor: 3.075

7.  Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods.

Authors:  S Wimsey; R Pickard; G Shaw
Journal:  J Bone Joint Surg Br       Date:  2006-11

8.  Disc calibration for digital templating in hip replacement.

Authors:  A Kulkarni; P Partington; D Kelly; S Muller
Journal:  J Bone Joint Surg Br       Date:  2008-12

9.  A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe?

Authors:  Richard Iorio; Jodi Siegel; Lawrence M Specht; John F Tilzey; Audrey Hartman; William L Healy
Journal:  J Arthroplasty       Date:  2008-03-28       Impact factor: 4.757

10.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

View more
  18 in total

1.  Radiographic templating of total hip arthroplasty for femoral neck fractures.

Authors:  Dror Lakstein; Ira Bachar; Ronen Debi; Omri Lubovsky; Ornit Cohen; Zachary Tan; Ehud Atoun
Journal:  Int Orthop       Date:  2016-06-07       Impact factor: 3.075

2.  Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities.

Authors:  M Pietsch; M Hochegger; O Djahani; G Mlaker; M Eder-Halbedl; Th Hofstädter
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-13       Impact factor: 3.067

3.  Radiographic Evaluation of Alignment Following TKA, a Systematic Review.

Authors:  Serban Dragosloveanu; Bogdan Cretu; Stefan Cristea; Cristian Stoica; Calin Dragosloveanu
Journal:  Maedica (Bucur)       Date:  2017-09

4.  Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative.

Authors:  Martijn G M Schotanus; Daphne A L Schoenmakers; Rob Sollie; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-05       Impact factor: 4.342

5.  Three-dimensional analysis of the proximal anterior femoral flare and torsion. Anatomic bases for metaphyseally fixed short stems design.

Authors:  Elhadi Sariali; Yohan Knaffo
Journal:  Int Orthop       Date:  2017-03-10       Impact factor: 3.075

6.  The impact of femoral bone quality on cementless total hip pre-operative templating.

Authors:  David Mevorach; Itay Perets; Alexander Greenberg; Leonid Kandel; Yoav Mattan; Meir Liebergall; Gurion Rivkin
Journal:  Int Orthop       Date:  2022-06-20       Impact factor: 3.479

7.  Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty.

Authors:  Tilman Graulich; Julius Gerhardy; Marcus Örgel; Tarek Omar-Pacha; Mohamed Omar; Christian Krettek; Daniel Guenther
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

8.  The accuracy of external calibration markers in digital templating using the double marker and single marker method: a comparative study.

Authors:  Y Warschawski; I Shichman; S Morgan; O Shaked; S Garceau; N Amzallag; N Snir; A Gold
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-13       Impact factor: 3.067

9.  Three-dimensional planning-guided total hip arthroplasty through a minimally invasive direct anterior approach. Clinical outcomes at five years' follow-up.

Authors:  Elhadi Sariali; Yves Catonne; Hugues Pascal-Moussellard
Journal:  Int Orthop       Date:  2016-06-16       Impact factor: 3.075

10.  Is analog preoperative planning still applicable?-comparison of accuracy of analog and computer preoperative planning methods in total hip arthroplasty.

Authors:  Julian Dutka; Slawomir Kiepura; Mateusz Bukowczan
Journal:  Ann Transl Med       Date:  2021-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.