Literature DB >> 19043135

Disc calibration for digital templating in hip replacement.

A Kulkarni1, P Partington, D Kelly, S Muller.   

Abstract

Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by 'reverse calibration' of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs.

Entities:  

Mesh:

Year:  2008        PMID: 19043135     DOI: 10.1302/0301-620X.90B12.20238

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Dual-position calibration markers for total hip arthroplasty: theoretical comparison to fixed calibration and single marker method.

Authors:  Christoph Kolja Boese; Sebastian Wilhelm; Stefan Haneder; Philipp Lechler; Peer Eysel; Jan Bredow
Journal:  Int Orthop       Date:  2018-06-20       Impact factor: 3.075

2.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

3.  Digital templating in total knee and hip replacement: an analysis of planning accuracy.

Authors:  Bettina Kniesel; Lukas Konstantinidis; Anja Hirschmüller; Norbert Südkamp; Peter Helwig
Journal:  Int Orthop       Date:  2013-10-27       Impact factor: 3.075

4.  Calibration Markers for Digital Templating in Total Hip Arthroplasty.

Authors:  Christoph Kolja Boese; Philipp Lechler; Leonard Rose; Jens Dargel; Johannes Oppermann; Peer Eysel; Hansjörg Geiges; Jan Bredow
Journal:  PLoS One       Date:  2015-07-13       Impact factor: 3.240

5.  Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Authors:  Tarun Goyal; Siddharth S Sethy; Sajid Ansari; Lakshmana Das; Souvik Paul
Journal:  Indian J Orthop       Date:  2020-11-03       Impact factor: 1.251

6.  Is analog preoperative planning still applicable?-comparison of accuracy of analog and computer preoperative planning methods in total hip arthroplasty.

Authors:  Julian Dutka; Slawomir Kiepura; Mateusz Bukowczan
Journal:  Ann Transl Med       Date:  2021-05

7.  Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates.

Authors:  Luis Fernando Useche Gómez; Hernando Gaitán-Lee; María Alejandra Duarte; Patrick Dennis Halley; Alejandro Romero Jaramillo; Efraim Leal García
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.