Literature DB >> 18534425

A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe?

Richard Iorio1, Jodi Siegel, Lawrence M Specht, John F Tilzey, Audrey Hartman, William L Healy.   

Abstract

The purposes of this study were to compare the accuracy of acetate and digital templating for primary total hip arthroplasty (THA) and to determine if digital templating is safe. Preoperative planning was performed on 50 consecutive preoperative radiographs during 2005. Templating results were compared with the actual hip implants used. Interrater reliability of acetate templating and accuracy of acetate and digital templating were recorded. Digital measurement overestimated acetabular size (P < .001) and underestimated the femoral size (P = .03). The absolute errors were larger for digital compared with acetate templating; however, mean absolute errors did not differ significantly (acetabulum, P = .090; femur, P = .114). Acetate and digital templating can accurately predict the size of THA implants. Digital templating was determined to be acceptably safe for preoperative planning of primary THA operations.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534425     DOI: 10.1016/j.arth.2007.11.019

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  28 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Inaccuracies in the Use of Magnification Markers in Digital Hip Radiographs.

Authors:  Michael J Archibeck; Tamara Cummins; Krishna R Tripuraneni; Joshua T Carothers; Cristina Murray-Krezan; Mohammad Hattab; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2016-01-21       Impact factor: 4.176

3.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

4.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

5.  Radiographic templating of total hip arthroplasty for femoral neck fractures.

Authors:  Dror Lakstein; Ira Bachar; Ronen Debi; Omri Lubovsky; Ornit Cohen; Zachary Tan; Ehud Atoun
Journal:  Int Orthop       Date:  2016-06-07       Impact factor: 3.075

6.  Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

Authors:  Karl Philipp Kutzner; Joachim Pfeil; Mark Predrag Kovacevic
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

7.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

8.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

9.  Significance of proximal femoral computed tomography scanning in the prediction of femoral prosthesis before total hip arthroplasty.

Authors:  Yizhong Li; Jinkuang Lin; Jing Zhang; Jianlong Li; Xuedong Yao; Huafeng Zhuang; Yanjun Zeng
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-01-29

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.