Literature DB >> 17075099

Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods.

S Wimsey1, R Pickard, G Shaw.   

Abstract

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient's thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery.

Entities:  

Mesh:

Year:  2006        PMID: 17075099     DOI: 10.1302/0301-620X.88B11.18017

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  18 in total

1.  Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software.

Authors:  S P White; J Bainbridge; E J Smith
Journal:  Ann R Coll Surg Engl       Date:  2008-10       Impact factor: 1.891

2.  Determination of digitised radiograph magnification factors for pre-operative templating in hip prosthesis surgery.

Authors:  Stephane Descamps; Christine Livesey; Ian Douglas Learmonth
Journal:  Skeletal Radiol       Date:  2009-09-16       Impact factor: 2.199

3.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

4.  Magnification error in digital radiographs of the cervical spine against magnetic resonance imaging measurements.

Authors:  Hideki Shigematsu; Munehisa Koizumi; Masana Yoneda; Jin Iida; Takuya Oshima; Yasuhito Tanaka
Journal:  Asian Spine J       Date:  2013-11-28

5.  Digital templating in total knee and hip replacement: an analysis of planning accuracy.

Authors:  Bettina Kniesel; Lukas Konstantinidis; Anja Hirschmüller; Norbert Südkamp; Peter Helwig
Journal:  Int Orthop       Date:  2013-10-27       Impact factor: 3.075

6.  The accuracy of external calibration markers in digital templating using the double marker and single marker method: a comparative study.

Authors:  Y Warschawski; I Shichman; S Morgan; O Shaked; S Garceau; N Amzallag; N Snir; A Gold
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-13       Impact factor: 3.067

7.  Assessment of magnification of digital radiographs in total HIP arthroplasty.

Authors:  Nuria I Olmedo-Garcia; Jose L Martínez Vergara; Tamara L Aparici Miralles; Juan V Sánchez Andrés; Adela Mesado Vives; Encarna Cruz Renovell; Vicente Granell Beltran
Journal:  J Orthop       Date:  2018-08-24

8.  Scaling Marker Position Determines the Accuracy of Digital Templating for Total Hip Arthroplasty.

Authors:  Austin J Ramme; Nina D Fisher; Jonathan Egol; Gregory Chang; Jonathan M Vigdorchik
Journal:  HSS J       Date:  2017-09-12

9.  Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Authors:  Tarun Goyal; Siddharth S Sethy; Sajid Ansari; Lakshmana Das; Souvik Paul
Journal:  Indian J Orthop       Date:  2020-11-03       Impact factor: 1.251

10.  Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates.

Authors:  Luis Fernando Useche Gómez; Hernando Gaitán-Lee; María Alejandra Duarte; Patrick Dennis Halley; Alejandro Romero Jaramillo; Efraim Leal García
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.