Literature DB >> 24107545

PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction.

J Webster Stayman1, Hao Dang, Yifu Ding, Jeffrey H Siewerdsen.   

Abstract

Over the course of diagnosis and treatment, it is common for a number of imaging studies to be acquired. Such imaging sequences can provide substantial patient-specific prior knowledge about the anatomy that can be incorporated into a prior-image-based tomographic reconstruction for improved image quality and better dose utilization. We present a general methodology using a model-based reconstruction approach including formulations of the measurement noise that also integrates prior images. This penalized-likelihood technique adopts a sparsity enforcing penalty that incorporates prior information yet allows for change between the current reconstruction and the prior image. Moreover, since prior images are generally not registered with the current image volume, we present a modified model-based approach that seeks a joint registration of the prior image in addition to the reconstruction of projection data. We demonstrate that the combined prior-image- and model-based technique outperforms methods that ignore the prior data or lack a noise model. Moreover, we demonstrate the importance of registration for prior-image-based reconstruction methods and show that the prior-image-registered penalized-likelihood estimation (PIRPLE) approach can maintain a high level of image quality in the presence of noisy and undersampled projection data.

Entities:  

Mesh:

Year:  2013        PMID: 24107545      PMCID: PMC3868341          DOI: 10.1088/0031-9155/58/21/7563

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  37 in total

1.  Maximum-likelihood transmission image reconstruction for overlapping transmission beams.

Authors:  D F Yu; J A Fessler; E P Ficaro
Journal:  IEEE Trans Med Imaging       Date:  2000-11       Impact factor: 10.048

2.  Interpolation revisited.

Authors:  P Thévenaz; T Blu; M Unser
Journal:  IEEE Trans Med Imaging       Date:  2000-07       Impact factor: 10.048

3.  Image reconstruction for transmission tomography when projection data are incomplete.

Authors:  Donald L Snyder; Joseph A O'Sullivan; Ryan J Murphy; David G Politte; Bruce R Whiting; Jeffrey F Williamson
Journal:  Phys Med Biol       Date:  2006-10-16       Impact factor: 3.609

4.  Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.

Authors:  Giovanni M Lasio; Bruce R Whiting; Jeffrey F Williamson
Journal:  Phys Med Biol       Date:  2007-04-02       Impact factor: 3.609

5.  Convergence of EM image reconstruction algorithms with Gibbs smoothing.

Authors:  K Lange
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

6.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.

Authors:  Joshua D Evans; David G Politte; Bruce R Whiting; Joseph A O'Sullivan; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

10.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

View more
  24 in total

1.  Deriving adaptive MRF coefficients from previous normal-dose CT scan for low-dose image reconstruction via penalized weighted least-squares minimization.

Authors:  Hao Zhang; Hao Han; Jing Wang; Jianhua Ma; Yan Liu; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

Review 2.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

3.  Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study.

Authors:  Yingxuan Chen; Fang-Fang Yin; Yawei Zhang; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2018-04-19       Impact factor: 3.609

4.  Reconstruction of difference in sequential CT studies using penalized likelihood estimation.

Authors:  A Pourmorteza; H Dang; J H Siewerdsen; J W Stayman
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

5.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

6.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

7.  Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

8.  dPIRPLE: a joint estimation framework for deformable registration and penalized-likelihood CT image reconstruction using prior images.

Authors:  H Dang; A S Wang; Marc S Sussman; J H Siewerdsen; J W Stayman
Journal:  Phys Med Biol       Date:  2014-08-06       Impact factor: 3.609

9.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

10.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging.

Authors:  H Dang; J W Stayman; A Sisniega; J Xu; W Zbijewski; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-07-30       Impact factor: 3.609

View more