Literature DB >> 11055789

Interpolation revisited.

P Thévenaz1, T Blu, M Unser.   

Abstract

Based on the theory of approximation, this paper presents a unified analysis of interpolation and resampling techniques. An important issue is the choice of adequate basis functions. We show that, contrary to the common belief, those that perform best are not interpolating. By opposition to traditional interpolation, we call their use generalized interpolation; they involve a prefiltering step when correctly applied. We explain why the approximation order inherent in any basis function is important to limit interpolation artifacts. The decomposition theorem states that any basis function endowed with approximation order can be expressed as the convolution of a B-spline of the same order with another function that has none. This motivates the use of splines and spline-based functions as a tunable way to keep artifacts in check without any significant cost penalty. We discuss implementation and performance issues, and we provide experimental evidence to support our claims.

Entities:  

Mesh:

Year:  2000        PMID: 11055789     DOI: 10.1109/42.875199

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  51 in total

1.  Cytoarchitectonic mapping of the human dorsal extrastriate cortex.

Authors:  Milenko Kujovic; Karl Zilles; Aleksandar Malikovic; Axel Schleicher; Hartmut Mohlberg; Claudia Rottschy; Simon B Eickhoff; Katrin Amunts
Journal:  Brain Struct Funct       Date:  2012-02-22       Impact factor: 3.270

2.  Novel framework for registration of pedobarographic image data.

Authors:  Francisco P M Oliveira; João Manuel R S Tavares
Journal:  Med Biol Eng Comput       Date:  2010-11-03       Impact factor: 2.602

3.  Can electronic zoom replace magnification in mammography? A comparative Monte Carlo study.

Authors:  M Koutalonis; H Delis; A Pascoal; G Spyrou; L Costaridou; G Panayiotakis
Journal:  Br J Radiol       Date:  2010-07       Impact factor: 3.039

4.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

5.  Retrospective distortion correction for 3D MR diffusion tensor microscopy using mutual information and Fourier deformations.

Authors:  Nilesh N Mistry; Edward W Hsu
Journal:  Magn Reson Med       Date:  2006-08       Impact factor: 4.668

6.  Volume reconstruction based on non-rigid registration.

Authors:  Xudong Bao; Danhua Xu; Christine Toumoulin; Limin Luo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

7.  Spatio-temporal alignment of pedobarographic image sequences.

Authors:  Francisco P M Oliveira; Andreia Sousa; Rubim Santos; João Manuel R S Tavares
Journal:  Med Biol Eng Comput       Date:  2011-04-08       Impact factor: 2.602

8.  Improved computer-aided detection of small polyps in CT colonography using interpolation for curvature estimation.

Authors:  Jiamin Liu; Suraj Kabadi; Robert Van Uitert; Nicholas Petrick; Rachid Deriche; Ronald M Summers
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

9.  Impact of MRI head placement on glioma response assessment.

Authors:  Martin Reuter; Elizabeth R Gerstner; Otto Rapalino; Tracy T Batchelor; Bruce Rosen; Bruce Fischl
Journal:  J Neurooncol       Date:  2014-02-25       Impact factor: 4.130

10.  4D reconstruction of the beating embryonic heart from two orthogonal sets of parallel optical coherence tomography slice-sequences.

Authors:  Sandeep Bhat; Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  IEEE Trans Med Imaging       Date:  2012-12-04       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.