Scatter characterization and correction for simultaneous multiple small-animal PET imaging.

Rameshwar Prasad1, Habib Zaidi.   

Abstract

PURPOSE: The rapid growth and usage of small-animal positron emission tomography (PET) in molecular imaging research has led to increased demand on PET scanner's time. One potential solution to increase throughput is to scan multiple rodents simultaneously. However, this is achieved at the expense of deterioration of image quality and loss of quantitative accuracy owing to enhanced effects of photon attenuation and Compton scattering. The purpose of this work is, first, to characterize the magnitude and spatial distribution of the scatter component in small-animal PET imaging when scanning single and multiple rodents simultaneously and, second, to assess the relevance and evaluate the performance of scatter correction under similar conditions.
METHODS: The LabPET™-8 scanner was modelled as realistically as possible using Geant4 Application for Tomographic Emission Monte Carlo simulation platform. Monte Carlo simulations allow the separation of unscattered and scattered coincidences and as such enable detailed assessment of the scatter component and its origin. Simple shape-based and more realistic voxel-based phantoms were used to simulate single and multiple PET imaging studies. The modelled scatter component using the single-scatter simulation technique was compared to Monte Carlo simulation results. PET images were also corrected for attenuation and the combined effect of attenuation and scatter on single and multiple small-animal PET imaging evaluated in terms of image quality and quantitative accuracy.
RESULTS: A good agreement was observed between calculated and Monte Carlo simulated scatter profiles for single- and multiple-subject imaging. In the LabPET™-8 scanner, the detector covering material (kovar) contributed the maximum amount of scatter events while the scatter contribution due to lead shielding is negligible. The out-of field-of-view (FOV) scatter fraction (SF) is 1.70, 0.76, and 0.11% for lower energy thresholds of 250, 350, and 400 keV, respectively. The increase in SF ranged between 25 and 64% when imaging multiple subjects (three to five) of different size simultaneously in comparison to imaging a single subject. The spill-over ratio (SOR) increases with increasing the number of subjects in the FOV. Scatter correction improved the SOR for both water and air cold compartments of single and multiple imaging studies. The recovery coefficients for different body parts of the mouse whole-body and rat whole-body anatomical models were improved for multiple imaging studies following scatter correction.
CONCLUSIONS: The magnitude and spatial distribution of the scatter component in small-animal PET imaging of single and multiple subjects simultaneously were characterized, and its impact was evaluated in different situations. Scatter correction improves PET image quality and quantitative accuracy for single rat and simultaneous multiple mice and rat imaging studies, whereas its impact is insignificant in single mouse imaging.

Entities:  

Mesh:

Year:  2014        PMID: 23990147     DOI: 10.1007/s11307-013-0683-2

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  25 in total

Review 1.  PET/CT: a new imaging technology in nuclear medicine.

Authors:  Heiko Schöder; Yusuf E Erdi; Steven M Larson; Henry W D Yeung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-05       Impact factor: 9.236

Review 2.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

3.  NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner.

Authors:  Rameshwar Prasad; Osman Ratib; Habib Zaidi
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

4.  Quantification accuracy and partial volume effect in dependence of the attenuation correction of a state-of-the-art small animal PET scanner.

Authors:  Julia G Mannheim; Martin S Judenhofer; Andreas Schmid; Julia Tillmanns; Detlef Stiller; Vesna Sossi; Bernd J Pichler
Journal:  Phys Med Biol       Date:  2012-05-31       Impact factor: 3.609

5.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

6.  Semiautomated analysis of small-animal PET data.

Authors:  Adam L Kesner; Magnus Dahlbom; Sung-Cheng Huang; Wei-Ann Hsueh; Betty S Pio; Johannes Czernin; Michael Kreissl; Hsiao-Ming Wu; Daniel H S Silverman
Journal:  J Nucl Med       Date:  2006-07       Impact factor: 10.057

7.  Automated analysis of small animal PET studies through deformable registration to an atlas.

Authors:  Daniel F Gutierrez; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-07-21       Impact factor: 9.236

Review 8.  Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences.

Authors:  Habib Zaidi; Xie George Xu
Journal:  Annu Rev Biomed Eng       Date:  2007       Impact factor: 9.590

9.  NEMA NU 4-2008 comparison of preclinical PET imaging systems.

Authors:  Andrew L Goertzen; Qinan Bao; Mélanie Bergeron; Eric Blankemeyer; Stephan Blinder; Mario Cañadas; Arion F Chatziioannou; Katherine Dinelle; Esmat Elhami; Hans-Sonke Jans; Eduardo Lage; Roger Lecomte; Vesna Sossi; Suleman Surti; Yuan-Chuan Tai; Juan José Vaquero; Esther Vicente; Darin A Williams; Richard Laforest
Journal:  J Nucl Med       Date:  2012-06-14       Impact factor: 10.057

10.  Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards.

Authors:  Qinan Bao; Danny Newport; Mu Chen; David B Stout; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057

View more
  3 in total

1.  NEMA NU 4-Optimized Reconstructions for Therapy Assessment in Cancer Research with the Inveon Small Animal PET/CT System.

Authors:  Charline Lasnon; Audrey Emmanuelle Dugue; Mélanie Briand; Cécile Blanc-Fournier; Soizic Dutoit; Marie-Hélène Louis; Nicolas Aide
Journal:  Mol Imaging Biol       Date:  2015-06       Impact factor: 3.488

2.  PET Imaging of Estrogen Receptors Using 18F-Based Radioligands.

Authors:  Manoj Kumar; Kelley Salem; Justin J Jeffery; Amy M Fowler
Journal:  Methods Mol Biol       Date:  2022

3.  Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance.

Authors:  Christian Vanhove; Jens P Bankstahl; Stefanie D Krämer; Eric Visser; Nicola Belcari; Stefaan Vandenberghe
Journal:  EJNMMI Phys       Date:  2015-11-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.