Literature DB >> 22820650

Automated analysis of small animal PET studies through deformable registration to an atlas.

Daniel F Gutierrez1, Habib Zaidi.   

Abstract

PURPOSE: This work aims to develop a methodology for automated atlas-guided analysis of small animal positron emission tomography (PET) data through deformable registration to an anatomical mouse model.
METHODS: A non-rigid registration technique is used to put into correspondence relevant anatomical regions of rodent CT images from combined PET/CT studies to corresponding CT images of the Digimouse anatomical mouse model. The latter provides a pre-segmented atlas consisting of 21 anatomical regions suitable for automated quantitative analysis. Image registration is performed using a package based on the Insight Toolkit allowing the implementation of various image registration algorithms. The optimal parameters obtained for deformable registration were applied to simulated and experimental mouse PET/CT studies. The accuracy of the image registration procedure was assessed by segmenting mouse CT images into seven regions: brain, lungs, heart, kidneys, bladder, skeleton and the rest of the body. This was accomplished prior to image registration using a semi-automated algorithm. Each mouse segmentation was transformed using the parameters obtained during CT to CT image registration. The resulting segmentation was compared with the original Digimouse atlas to quantify image registration accuracy using established metrics such as the Dice coefficient and Hausdorff distance. PET images were then transformed using the same technique and automated quantitative analysis of tracer uptake performed.
RESULTS: The Dice coefficient and Hausdorff distance show fair to excellent agreement and a mean registration mismatch distance of about 6 mm. The results demonstrate good quantification accuracy in most of the regions, especially the brain, but not in the bladder, as expected. Normalized mean activity estimates were preserved between the reference and automated quantification techniques with relative errors below 10 % in most of the organs considered.
CONCLUSION: The proposed automated quantification technique is reliable, robust and suitable for fast quantification of preclinical PET data in large serial studies.

Entities:  

Mesh:

Year:  2012        PMID: 22820650      PMCID: PMC3464388          DOI: 10.1007/s00259-012-2188-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  35 in total

1.  A stereotactic method for the three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology, and autoradiography.

Authors:  J L Humm; D Ballon; Y C Hu; S Ruan; C Chui; P K Tulipano; A Erdi; J Koutcher; K Zakian; M Urano; P Zanzonico; C Mattis; J Dyke; Y Chen; P Harrington; J A O'Donoghue; C C Ling
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

2.  Development and evaluation of an automated atlas-based image analysis method for microPET studies of the rat brain.

Authors:  Daniel J Rubins; William P Melega; Goran Lacan; Baldwin Way; Alain Plenevaux; Andre Luxen; Simon R Cherry
Journal:  Neuroimage       Date:  2003-12       Impact factor: 6.556

3.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

Authors:  Belma Dogdas; David Stout; Arion F Chatziioannou; Richard M Leahy
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

4.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

5.  Deformable and rigid registration of MRI and microPET images for photodynamic therapy of cancer in mice.

Authors:  Baowei Fei; Hesheng Wang; Raymond F Muzic; Chris Flask; David L Wilson; Jeffrey L Duerk; Denise K Feyes; Nancy L Oleinick
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

6.  Atlas-based whole-body segmentation of mice from low-contrast Micro-CT data.

Authors:  Martin Baiker; Julien Milles; Jouke Dijkstra; Tobias D Henning; Axel W Weber; Ivo Que; Eric L Kaijzel; Clemens W G M Löwik; Johan H C Reiber; Boudewijn P F Lelieveldt
Journal:  Med Image Anal       Date:  2010-05-21       Impact factor: 8.545

7.  Multimodality imaging of tumor xenografts and metastases in mice with combined small-animal PET, small-animal CT, and bioluminescence imaging.

Authors:  Christophe M Deroose; Abhijit De; Andreas M Loening; Patrick L Chow; Pritha Ray; Arion F Chatziioannou; Sanjiv S Gambhir
Journal:  J Nucl Med       Date:  2007-02       Impact factor: 10.057

8.  Construction and evaluation of multitracer small-animal PET probabilistic atlases for voxel-based functional mapping of the rat brain.

Authors:  Cindy Casteels; Peter Vermaelen; Johan Nuyts; Annemie Van Der Linden; Veerle Baekelandt; Luc Mortelmans; Guy Bormans; Koen Van Laere
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

9.  Development of a 4-D digital mouse phantom for molecular imaging research.

Authors:  William P Segars; Benjamin M W Tsui; Eric C Frey; G Allan Johnson; Stuart S Berr
Journal:  Mol Imaging Biol       Date:  2004 May-Jun       Impact factor: 3.488

10.  An image-based rat model for Monte Carlo organ dose calculations.

Authors:  Li Wu; Guozhi Zhang; Qingming Luo; Qian Liu
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  8 in total

1.  Scatter characterization and correction for simultaneous multiple small-animal PET imaging.

Authors:  Rameshwar Prasad; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2014-04       Impact factor: 3.488

2.  Evaluation of whole-body MR to CT deformable image registration.

Authors:  A Akbarzadeh; D Gutierrez; A Baskin; M R Ay; A Ahmadian; N Riahi Alam; K O Lövblad; H Zaidi
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

3.  Automated MicroSPECT/MicroCT Image Analysis of the Mouse Thyroid Gland.

Authors:  Peng Cheng; Brynn Hollingsworth; Daniel Scarberry; Daniel H Shen; Kimerly Powell; Sean C Smart; John Beech; Xiaochao Sheng; Lawrence S Kirschner; Chia-Hsiang Menq; Sissy M Jhiang
Journal:  Thyroid       Date:  2017-10-19       Impact factor: 6.568

4.  An Automatic Method for Generating an Unbiased Intensity Normalizing Factor in Positron Emission Tomography Image Analysis After Stroke.

Authors:  Binbin Nie; Shengxiang Liang; Xiaofeng Jiang; Shaofeng Duan; Qi Huang; Tianhao Zhang; Panlong Li; Hua Liu; Baoci Shan
Journal:  Neurosci Bull       Date:  2018-06-07       Impact factor: 5.203

5.  Three-dimensional reconstruction of brain structures of the rodent Octodon degus: a brain atlas constructed by combining histological and magnetic resonance images.

Authors:  Noriko Kumazawa-Manita; Mariko Katayama; Tsutomu Hashikawa; Atsushi Iriki
Journal:  Exp Brain Res       Date:  2013-08-31       Impact factor: 1.972

6.  Automated quantification of bioluminescence images.

Authors:  Alexander D Klose; Neal Paragas
Journal:  Nat Commun       Date:  2018-10-15       Impact factor: 14.919

7.  Automatic method for individual parcellation of manganese-enhanced magnetic resonance imaging of rat brain.

Authors:  Zhiguo Bao; Tianhao Zhang; Tingting Pan; Wei Zhang; Shilun Zhao; Hua Liu; Binbin Nie
Journal:  Front Neurosci       Date:  2022-07-28       Impact factor: 5.152

8.  Construction and evaluation of quantitative small-animal PET probabilistic atlases for [¹⁸F]FDG and [¹⁸F]FECT functional mapping of the mouse brain.

Authors:  Cindy Casteels; Kathleen Vunckx; Sarah-Ann Aelvoet; Veerle Baekelandt; Guy Bormans; Koen Van Laere; Michel Koole
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.