PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.
PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.
Authors: Jin Pyo Hong; Sang Min Nam; Tae-Im Kim; Kyoung Yul Seo; Sang Yeop Lee; Alessandro Meduri; Eung Kweon Kim Journal: Yonsei Med J Date: 2012-05 Impact factor: 2.759