Literature DB >> 23918579

Comparison of preoperative and postoperative ocular biometry in eyes with phakic intraocular lens implantations.

Joo Youn Shin1, Jae Bum Lee, Kyoung Yul Seo, Eung Kweon Kim, Tae-im Kim.   

Abstract

PURPOSE: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex.
MATERIALS AND METHODS: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation.
RESULTS: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL.
CONCLUSION: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.

Entities:  

Keywords:  Biometry; anterior chamber depth; axial length; phakic intraocular lenses

Mesh:

Year:  2013        PMID: 23918579      PMCID: PMC3743187          DOI: 10.3349/ymj.2013.54.5.1259

Source DB:  PubMed          Journal:  Yonsei Med J        ISSN: 0513-5796            Impact factor:   2.759


  21 in total

1.  Ocular component measurement using the Zeiss IOLMaster.

Authors:  Huan Sheng; Carol A Bottjer; Mark A Bullimore
Journal:  Optom Vis Sci       Date:  2004-01       Impact factor: 1.973

2.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

3.  Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calculation.

Authors:  Loreto T Rose; Con N Moshegov
Journal:  Clin Exp Ophthalmol       Date:  2003-04       Impact factor: 4.207

4.  [Optical biometry of eyes corrected by phakic intraocular lenses].

Authors:  G Pitault; C Leboeuf; S Leroux les Jardins; F Auclin; D Chong-Sit; C Baudouin
Journal:  J Fr Ophtalmol       Date:  2005-12       Impact factor: 0.818

5.  Bilateral giant tear-associated retinal detachment following Artisan phakic intraocular lens implantation for correction of moderate myopia.

Authors:  Ilias Georgalas; Petros Petrou; Dimitris Papaconstantinou; Chrysanthi Koutsandrea; Ioannis Ladas
Journal:  Acta Ophthalmol       Date:  2009-06-22       Impact factor: 3.761

6.  Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations.

Authors:  J T Holladay
Journal:  J Cataract Refract Surg       Date:  1997-11       Impact factor: 3.351

7.  Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant.

Authors:  M Vetrugno; N Cardascia; L Cardia
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

8.  Ultrasound axial length measurement in biphakic eyes.

Authors:  Kenneth J Hoffer
Journal:  J Cataract Refract Surg       Date:  2003-05       Impact factor: 3.351

Review 9.  Cataract surgery following phakic intraocular lens implantation.

Authors:  Majid Moshirfar; Mark Mifflin; Gilbert Wong; Joann C Chang
Journal:  Curr Opin Ophthalmol       Date:  2010-01       Impact factor: 3.761

10.  Reliability of RTVue, Visante, and slit-lamp adapted ultrasonic pachymetry for central corneal thickness measurement.

Authors:  Jin Pyo Hong; Sang Min Nam; Tae-Im Kim; Kyoung Yul Seo; Sang Yeop Lee; Alessandro Meduri; Eung Kweon Kim
Journal:  Yonsei Med J       Date:  2012-05       Impact factor: 2.759

View more
  2 in total

1.  Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes.

Authors:  Hun Lee; Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

2.  Artisan versus Artiflex phakic intraocular lens implantation in the treatment of moderate to high myopia: meta-analysis.

Authors:  Chenting Hou; Hui Li; Jiangfeng Li; Jinjian Li; Hui Peng; Qing Wang
Journal:  BMC Ophthalmol       Date:  2021-04-10       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.