Clinical impact of an adaptive statistical iterative reconstruction algorithm for detection of hypervascular liver tumours using a low tube voltage, high tube current MDCT technique.

Daniele Marin1, Kingshuk Roy Choudhury, Rajan T Gupta, Lisa M Ho, Brian C Allen, Sebastian T Schindera, James G Colsher, Ehsan Samei, Rendon C Nelson.   

Abstract

OBJECTIVES: To investigate the impact of an adaptive statistical iterative reconstruction (ASiR) algorithm on diagnostic accuracy and confidence for the diagnosis of hypervascular liver tumours, as well as the reader's perception of image quality, using a low tube voltage (80 kVp), high tube current computed tomography (CT) technique.
METHODS: Forty patients (29 men, 11 women) with 65 hypervascular liver tumours underwent dual energy CT. The 80 kV set of the dual energy acquisition was reconstructed with standard filtered backprojection (FBP) and ASiR at different blending levels. Lesion contrast-to-noise ratio (CNR), reader's confidence for lesion detection and characterisation, and reader's evaluation of image quality were recorded.
RESULTS: ASiR yielded significantly higher CNR values compared with FBP (P < 0.0001 for all comparisons). Reader's perception of lesion conspicuity and confidence in the diagnosis of malignancy were also higher with 60 % and 80 % ASiR, compared with FBP (P = 0.01 and < 0.001, respectively). Compared with FBP, ASiR yielded nearly significantly lower specificity for lesion detection and a substantial decrease in the reader's perception of image quality.
CONCLUSIONS: Compared with the standard FBP algorithm, ASiR significantly improves conspicuity of hypervascular liver lesions. This improvement may come at the cost of decreased specificity and reader's perception of image quality.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23832320     DOI: 10.1007/s00330-013-2964-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Focal liver lesions: pattern-based classification scheme for enhancement at arterial phase CT.

Authors:  M Nino-Murcia; E W Olcott; R B Jeffrey; R L Lamm; C F Beaulieu; K A Jain
Journal:  Radiology       Date:  2000-06       Impact factor: 11.105

3.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

4.  Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Avinash K Kambadakone; Homer Pien; Jiang Hsieh; Michael A Blake; Dushyant V Sahani
Journal:  Invest Radiol       Date:  2010-04       Impact factor: 6.016

5.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Radiation dose reduction at multidetector CT with adaptive statistical iterative reconstruction for evaluation of urolithiasis: how low can we go?

Authors:  Naveen M Kulkarni; Raul N Uppot; Brian H Eisner; Dushyant V Sahani
Journal:  Radiology       Date:  2012-08-13       Impact factor: 11.105

7.  Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Jiang Hsieh; Paul E Licato; Synho Do; Homer H Pien; Michael A Blake
Journal:  Radiology       Date:  2010-09-09       Impact factor: 11.105

8.  Impact of pretransplant diagnosis of hepatocellular carcinoma on cadveric liver allocation in the era of MELD.

Authors:  Paul H Hayashi; James F Trotter; Lisa Forman; Marcelo Kugelmas; Tracy Steinberg; Paul Russ; Michael Wachs; Thomas Bak; Igal Kam; Gregory T Everson
Journal:  Liver Transpl       Date:  2004-01       Impact factor: 5.799

9.  Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Ehsan Samei; Erik K Paulson; Lisa M Ho; Daniel T Boll; David M DeLong; Terry T Yoshizumi; Sebastian T Schindera
Journal:  Radiology       Date:  2009-04-03       Impact factor: 11.105

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  17 in total

1.  Aortic CT angiography dose reduction: investigation of optimal noise index and iterative algorithm strength in combination with low kV.

Authors:  Osvaldo Rampado; Stefania Busso; Domenica Garabello; Ezio Marengo; Marco Valerio; Simona Capello; Simona Veglia; Ottavio Davini; Roberto Ropolo
Journal:  Radiol Med       Date:  2015-12-16       Impact factor: 3.469

2.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

3.  Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Authors:  Ping Hou; Xiangnan Feng; Jie Liu; Yue Zhou; Yaojun Jiang; Xiaochen Jiang; Jianbo Gao
Journal:  Br J Radiol       Date:  2017-06-23       Impact factor: 3.039

4.  Iterative reconstruction improves image quality and preserves diagnostic accuracy in the setting of blunt solid organ injuries.

Authors:  Scott D Steenburg; Scott Persohn; Changyu Shen; Jeff W Dunkle; Sean D Gussick; Matthew J Petersen; Amy Wisnewski-Rhodes; Ryan T Whitesell
Journal:  Emerg Radiol       Date:  2014-06-07

5.  Dose reduction in abdominal CT: The road to submillisievert imaging.

Authors:  Alexander A Fingerle; Peter B Noël
Journal:  Eur Radiol       Date:  2018-04-10       Impact factor: 5.315

6.  Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction.

Authors:  Diomidis Botsikas; Isabelle Barnaure; Sylvain Terraz; Christoph D Becker; Anastasia Kalovidouri; Xavier Montet
Journal:  World J Radiol       Date:  2016-07-28

7.  Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction.

Authors:  Joel G Fletcher; Lifeng Yu; Zhoubo Li; Armando Manduca; Daniel J Blezek; David M Hough; Sudhakar K Venkatesh; Gregory C Brickner; Joseph C Cernigliaro; Amy K Hara; Jeff L Fidler; David S Lake; Maria Shiung; David Lewis; Shuai Leng; Kurt E Augustine; Rickey E Carter; David R Holmes; Cynthia H McCollough
Journal:  Radiology       Date:  2015-05-26       Impact factor: 11.105

8.  Hypodense liver lesions in patients with hepatic steatosis: do we profit from dual-energy computed tomography?

Authors:  Johanna Nattenmüller; Waldemar Hosch; Tri-Thien Nguyen; Stephan Skornitzke; Andreas Jöres; Lars Grenacher; Hans-Ulrich Kauczor; Christof M Sommer; Wolfram Stiller
Journal:  Eur Radiol       Date:  2015-05-17       Impact factor: 5.315

9.  CT reconstruction algorithms affect histogram and texture analysis: evidence for liver parenchyma, focal solid liver lesions, and renal cysts.

Authors:  Su Joa Ahn; Jung Hoon Kim; Sang Min Lee; Sang Joon Park; Joon Koo Han
Journal:  Eur Radiol       Date:  2018-11-19       Impact factor: 5.315

10.  Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge.

Authors:  Cynthia H McCollough; Adam C Bartley; Rickey E Carter; Baiyu Chen; Tammy A Drees; Phillip Edwards; David R Holmes; Alice E Huang; Farhana Khan; Shuai Leng; Kyle L McMillan; Gregory J Michalak; Kristina M Nunez; Lifeng Yu; Joel G Fletcher
Journal:  Med Phys       Date:  2017-10       Impact factor: 4.071