Literature DB >> 27551339

Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction.

Diomidis Botsikas1, Isabelle Barnaure1, Sylvain Terraz1, Christoph D Becker1, Anastasia Kalovidouri1, Xavier Montet1.   

Abstract

AIM: To evaluate the image quality of hepatic multidetector computed tomography (MDCT) with dynamic contrast enhancement.
METHODS: It uses iodixanol 270 mg/mL (Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction (SAFIRE(®)) in comparison with a standard MDCT protocol. Fifty-three consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/mL (Accupaque 350(®)) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively (SAFIRE(®)-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio (CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.
RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol (P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different (P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group (P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups (P = 0.9926).
CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.

Entities:  

Keywords:  Iso-osmolar iodine contrast agent; Iterative reconstruction; Low iodine concentration contrast agent; Low-kVp computed tomography; Multiphasic dynamic liver computed tomography

Year:  2016        PMID: 27551339      PMCID: PMC4965353          DOI: 10.4329/wjr.v8.i7.693

Source DB:  PubMed          Journal:  World J Radiol        ISSN: 1949-8470


  20 in total

1.  Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256-detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality.

Authors:  Takeshi Nakaura; Shinichi Nakamura; Natsuki Maruyama; Yoshinori Funama; Kazuo Awai; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  Radiology       Date:  2012-05-24       Impact factor: 11.105

2.  Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Synho Do; Jean Baptiste Thibault; Homer Pien; Owen J O'Connor; Owen O J Connor; Michael A Blake
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection.

Authors:  Roh-Eul Yoo; Eun-Ah Park; Whal Lee; Hackjoon Shim; Yeo Koon Kim; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-26       Impact factor: 2.357

5.  Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Duo Liu; Takeshi Nakaura; Yoshitaka Tamura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2006-11       Impact factor: 3.959

6.  Low voltage CTPA for patients with suspected pulmonary embolism.

Authors:  Giulia A Zamboni; Stefania Guariglia; Alberto Bonfante; Cristian Martino; Carlo Cavedon; Roberto Pozzi Mucelli
Journal:  Eur J Radiol       Date:  2011-07-16       Impact factor: 3.528

7.  Clinical impact of an adaptive statistical iterative reconstruction algorithm for detection of hypervascular liver tumours using a low tube voltage, high tube current MDCT technique.

Authors:  Daniele Marin; Kingshuk Roy Choudhury; Rajan T Gupta; Lisa M Ho; Brian C Allen; Sebastian T Schindera; James G Colsher; Ehsan Samei; Rendon C Nelson
Journal:  Eur Radiol       Date:  2013-07-06       Impact factor: 5.315

8.  Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Ehsan Samei; Erik K Paulson; Lisa M Ho; Daniel T Boll; David M DeLong; Terry T Yoshizumi; Sebastian T Schindera
Journal:  Radiology       Date:  2009-04-03       Impact factor: 11.105

Review 9.  Main results of the first comparative clinical studies on Visipaque.

Authors:  B H Grynne; J O Nossen; B Bolstad; K W Borch
Journal:  Acta Radiol Suppl       Date:  1995

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  3 in total

1.  Prospective multicenter study on personalized and optimized MDCT contrast protocols: results on liver enhancement.

Authors:  F Zanca; H G Brat; P Pujadas; D Racine; B Dufour; D Fournier; B Rizk
Journal:  Eur Radiol       Date:  2021-04-29       Impact factor: 5.315

2.  CARE Dose 4D combined with sinogram-affirmed iterative reconstruction improved the image quality and reduced the radiation dose in low dose CT of the small intestine.

Authors:  Lin Wang; Shenchu Gong; Jushun Yang; Jie Zhou; Jing Xiao; Jin-Hua Gu; Hong Yang; Jianfeng Zhu; Bosheng He
Journal:  J Appl Clin Med Phys       Date:  2018-12-03       Impact factor: 2.102

3.  The Image Quality and Diagnostic Performance of CT with Low-Concentration Iodine Contrast (240 mg Iodine/mL) for the Abdominal Organs.

Authors:  Moon-Hyung Choi; Young-Joon Lee; Seung-Eun Jung
Journal:  Diagnostics (Basel)       Date:  2022-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.