Literature DB >> 23828606

Multiple-echo diffusion tensor acquisition technique (MEDITATE) on a 3T clinical scanner.

Steven H Baete1, Gene Cho, Eric E Sigmund.   

Abstract

This article describes the concepts and implementation of an MRI method, the multiple-echo diffusion tensor acquisition technique (MEDITATE), which is capable of acquiring apparent diffusion tensor maps in two scans on a 3T clinical scanner. In each MEDITATE scan, a set of RF pulses generates multiple echoes, the amplitudes of which are diffusion weighted in both magnitude and direction by a pattern of diffusion gradients. As a result, two scans acquired with different diffusion weighting strengths suffice for accurate estimation of diffusion tensor imaging (DTI) parameters. The MEDITATE variation presented here expands previous MEDITATE approaches to adapt to the clinical scanner platform, such as exploiting longitudinal magnetization storage to reduce T2 weighting. Fully segmented multi-shot Cartesian encoding is used for image encoding. MEDITATE was tested on isotropic (agar gel), anisotropic diffusion phantoms (asparagus) and in vivo skeletal muscle in healthy volunteers with cardiac gating. Comparisons of accuracy were performed with standard twice-refocused spin echo (TRSE) DTI in each case and good quantitative agreement was found between diffusion eigenvalues, mean diffusivity and fractional anisotropy derived from TRSE DTI and from the MEDITATE sequence. Orientation patterns were correctly reproduced in both isotropic and anisotropic phantoms, and approximately for in vivo imaging. This illustrates that the MEDITATE method of compressed diffusion encoding is feasible on the clinical scanner platform. With future development and employment of appropriate view-sharing image encoding, this technique may be used in clinical applications requiring time-sensitive acquisition of DTI parameters such as dynamical DTI in muscle.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  DTI; diffusion; multiple-modulation multiple echo

Mesh:

Year:  2013        PMID: 23828606      PMCID: PMC3800503          DOI: 10.1002/nbm.2978

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  56 in total

1.  Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI.

Authors:  S Skare; M Hedehus; M E Moseley; T Q Li
Journal:  J Magn Reson       Date:  2000-12       Impact factor: 2.229

2.  Anisotropic noise propagation in diffusion tensor MRI sampling schemes.

Authors:  P G Batchelor; D Atkinson; D L G Hill; F Calamante; A Connelly
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

3.  Diffusive sensitivity to muscle architecture: a magnetic resonance diffusion tensor imaging study of the human calf.

Authors:  Craig J Galbán; Stefan Maderwald; Kai Uffmann; Armin de Greiff; Mark E Ladd
Journal:  Eur J Appl Physiol       Date:  2004-12       Impact factor: 3.078

4.  Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Authors:  Chunlei Liu; Michael E Moseley; Roland Bammer
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

5.  Tensor splines for interpolation and approximation of DT-MRI with applications to segmentation of isolated rat hippocampi.

Authors:  Angelos Barmpoutis; Baba C Vemuri; Timothy M Shepherd; John R Forder
Journal:  IEEE Trans Med Imaging       Date:  2007-11       Impact factor: 10.048

6.  A single-scan method for measuring flow along an arbitrary direction.

Authors:  H Cho; X-H Ren; E E Sigmund; Y-Q Song
Journal:  J Magn Reson       Date:  2007-01-12       Impact factor: 2.229

7.  A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features.

Authors:  Daniel C Alexander
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

8.  A diffusion gradient optimization framework for spinal cord diffusion tensor imaging.

Authors:  Shantanu Majumdar; David C Zhu; Satish S Udpa; L Guy Raguin
Journal:  Magn Reson Imaging       Date:  2011-05-08       Impact factor: 2.546

9.  A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords.

Authors:  V Gulani; G A Iwamoto; H Jiang; J S Shimony; A G Webb; P C Lauterbur
Journal:  Magn Reson Med       Date:  1997-12       Impact factor: 4.668

10.  Reproducibility analysis of diffusion tensor indices and fiber architecture of human calf muscles in vivo at 1.5 Tesla in neutral and plantarflexed ankle positions at rest.

Authors:  Shantanu Sinha; Usha Sinha
Journal:  J Magn Reson Imaging       Date:  2011-05-23       Impact factor: 4.813

View more
  6 in total

1.  Dynamic diffusion-tensor measurements in muscle tissue using the single-line multiple-echo diffusion-tensor acquisition technique at 3T.

Authors:  Steven H Baete; Gene Y Cho; Eric E Sigmund
Journal:  NMR Biomed       Date:  2015-04-22       Impact factor: 4.044

Review 2.  Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook.

Authors:  Els Fieremans; Hong-Hsi Lee
Journal:  Neuroimage       Date:  2018-06-18       Impact factor: 6.556

3.  Accelerated radial diffusion spectrum imaging using a multi-echo stimulated echo diffusion sequence.

Authors:  Steven H Baete; Fernando E Boada
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

4.  Spatially resolved kinetics of skeletal muscle exercise response and recovery with multiple echo diffusion tensor imaging (MEDITI): a feasibility study.

Authors:  E E Sigmund; S H Baete; K Patel; D Wang; D Stoffel; R Otazo; P Parasoglou; J Bencardino
Journal:  MAGMA       Date:  2018-05-14       Impact factor: 2.310

5.  Experimental considerations for fast kurtosis imaging.

Authors:  Brian Hansen; Torben E Lund; Ryan Sangill; Ebbe Stubbe; Jürgen Finsterbusch; Sune Nørhøj Jespersen
Journal:  Magn Reson Med       Date:  2015-11-26       Impact factor: 4.668

6.  MRI assessment of the thigh musculature in dermatomyositis and healthy subjects using diffusion tensor imaging, intravoxel incoherent motion and dynamic DTI.

Authors:  E E Sigmund; S H Baete; T Luo; K Patel; D Wang; I Rossi; A Duarte; M Bruno; D Mossa; A Femia; S Ramachandran; D Stoffel; J S Babb; A G Franks; J Bencardino
Journal:  Eur Radiol       Date:  2018-06-04       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.