Steven H Baete1,2, Fernando E Boada1,2. 1. Center for Advanced Imaging Innovation and Research (CAI2R), NYU School of Medicine, New York, New York, USA. 2. Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, New York, USA.
Abstract
PURPOSE: Diffusion spectrum imaging (DSI) provides us non-invasively and robustly with anatomical details of brain microstructure. To achieve sufficient angular resolution, DSI requires a large number of q-space samples, leading to long acquisition times. This need is mitigated here by combining the beneficial properties of Radial q-space sampling for DSI with a Multi-Echo Stimulated Echo Sequence (MESTIM). METHODS: Full 2D k-spaces for each of several q-space samples, along the same radially outward line in q-space, are acquired in one readout train with one spin and three stimulated echoes. RF flip angles are carefully chosen to distribute spin magnetization over the echoes and the DSI reconstruction is adapted to account for differences in diffusion time among echoes. RESULTS: Individual datasets and bootstrapped reproducibility analysis demonstrate image quality and SNR of the more-than-twofold-accelerated RDSI MESTIM sequence. Orientation distribution functions (ODF) and tractography results benefit from the longer diffusion times of the latter echoes in the echo train. CONCLUSION: A MESTIM sequence can be used to shorten RDSI acquisition times significantly without loss of image or ODF quality. Further acceleration is possible by combination with simultaneous multi-slice techniques. Magn Reson Med 79:306-316, 2018.
PURPOSE: Diffusion spectrum imaging (DSI) provides us non-invasively and robustly with anatomical details of brain microstructure. To achieve sufficient angular resolution, DSI requires a large number of q-space samples, leading to long acquisition times. This need is mitigated here by combining the beneficial properties of Radial q-space sampling for DSI with a Multi-Echo Stimulated Echo Sequence (MESTIM). METHODS: Full 2D k-spaces for each of several q-space samples, along the same radially outward line in q-space, are acquired in one readout train with one spin and three stimulated echoes. RF flip angles are carefully chosen to distribute spin magnetization over the echoes and the DSI reconstruction is adapted to account for differences in diffusion time among echoes. RESULTS: Individual datasets and bootstrapped reproducibility analysis demonstrate image quality and SNR of the more-than-twofold-accelerated RDSI MESTIM sequence. Orientation distribution functions (ODF) and tractography results benefit from the longer diffusion times of the latter echoes in the echo train. CONCLUSION: A MESTIM sequence can be used to shorten RDSI acquisition times significantly without loss of image or ODF quality. Further acceleration is possible by combination with simultaneous multi-slice techniques. Magn Reson Med 79:306-316, 2018.
Authors: David S Tuch; Timothy G Reese; Mette R Wiegell; Nikos Makris; John W Belliveau; Van J Wedeen Journal: Magn Reson Med Date: 2002-10 Impact factor: 4.668
Authors: Susumu Mori; Walter E Kaufmann; Christos Davatzikos; Bram Stieltjes; Laura Amodei; Kim Fredericksen; Godfrey D Pearlson; Elias R Melhem; Meiyappan Solaiyappan; Gerald V Raymond; Hugo W Moser; Peter C M van Zijl Journal: Magn Reson Med Date: 2002-02 Impact factor: 4.668
Authors: Van J Wedeen; Douglas L Rosene; Ruopeng Wang; Guangping Dai; Farzad Mortazavi; Patric Hagmann; Jon H Kaas; Wen-Yih I Tseng Journal: Science Date: 2012-03-30 Impact factor: 47.728
Authors: Mark Jenkinson; Christian F Beckmann; Timothy E J Behrens; Mark W Woolrich; Stephen M Smith Journal: Neuroimage Date: 2011-09-16 Impact factor: 6.556
Authors: P S Tofts; D Lloyd; C A Clark; G J Barker; G J Parker; P McConville; C Baldock; J M Pope Journal: Magn Reson Med Date: 2000-03 Impact factor: 4.668
Authors: Steven H Baete; Martijn A Cloos; Ying-Chia Lin; Dimitris G Placantonakis; Timothy Shepherd; Fernando E Boada Journal: Neuroimage Date: 2019-05-16 Impact factor: 6.556
Authors: Qiyuan Tian; Grant Yang; Christoph Leuze; Ariel Rokem; Brian L Edlow; Jennifer A McNab Journal: Neuroimage Date: 2019-01-23 Impact factor: 6.556