Literature DB >> 16276497

Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Chunlei Liu1, Michael E Moseley, Roland Bammer.   

Abstract

Phase-navigated multi-shot acquisition and parallel imaging are two techniques that have been applied to diffusion-weighted imaging (DWI) to diminish distortions and to enhance spatial resolution. Specifically, sensitivity encoding (SENSE) has been combined with single-shot echo planar imaging (EPI). Thus far, it has been difficult to apply parallel imaging methods, like SENSE, to multi-shot DWI because motion-induced phase error varies from shot to shot and interferes with sensitivity encoding. Although direct phase subtraction methods have been introduced to correct this phase error, they generally are not suitable for SENSE reconstruction, and they cannot remove all the motion artifacts even if the phase error is fully known. Here, an effective algorithm is proposed to correct the motion-induced phase error using an iterative reconstruction. In this proposed conjugate-gradient (CG) algorithm, the phase error is treated as an image encoding function. Given the complex perturbation terms, diffusion-weighted images can be reconstructed using an augmented sensitivity map. The mathematical formulation and image reconstruction procedures of this algorithm are similar to the SENSE reconstruction. By defining a dynamic composite sensitivity, the CG phase correction method can be conveniently incorporated with SENSE reconstruction for the application of multi-shot SENSE DWI. Effective phase correction and multi-shot SENSE DWI (R = 1 to 3) are demonstrated on both simulated and in vivo data acquired with PROPELLER and SNAILS.

Mesh:

Year:  2005        PMID: 16276497     DOI: 10.1002/mrm.20706

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

1.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

3.  Parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA).

Authors:  Chunlei Liu; Roland Bammer; Michael E Moseley
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

4.  Dynamic diffusion-tensor measurements in muscle tissue using the single-line multiple-echo diffusion-tensor acquisition technique at 3T.

Authors:  Steven H Baete; Gene Y Cho; Eric E Sigmund
Journal:  NMR Biomed       Date:  2015-04-22       Impact factor: 4.044

5.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

6.  Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Authors:  Shayan Guhaniyogi; Mei-Lan Chu; Hing-Chiu Chang; Allen W Song; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

7.  Sliding-window sensitivity encoding (SENSE) calibration for reducing noise in functional MRI (fMRI).

Authors:  Christine S Law; Chunlei Liu; Gary H Glover
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

8.  White matter pathology isolates the hippocampal formation in Alzheimer's disease.

Authors:  D H Salat; D S Tuch; A J W van der Kouwe; D N Greve; V Pappu; S Y Lee; N D Hevelone; A K Zaleta; J H Growdon; S Corkin; B Fischl; H D Rosas
Journal:  Neurobiol Aging       Date:  2010-02       Impact factor: 4.673

9.  High-resolution multishot spiral diffusion tensor imaging with inherent correction of motion-induced phase errors.

Authors:  Trong-Kha Truong; Arnaud Guidon
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  In vivo generalized diffusion tensor imaging (GDTI) using higher-order tensors (HOT).

Authors:  Chunlei Liu; Sarah C Mang; Michael E Moseley
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.