Literature DB >> 9402185

A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords.

V Gulani1, G A Iwamoto, H Jiang, J S Shimony, A G Webb, P C Lauterbur.   

Abstract

A new imaging sequence for rapid determination of the apparent self-diffusion tensor of water was developed and tested on fixed excised rat spinal cords. To reduce the time required to determine the tensor, the sequence utilized a new single-shot approach with multiple spin echoes. An assumption of cylindrical symmetry in the sample was made, thus requiring the measurement of only four of the six unique elements of the tensor. This assumption was found experimentally to be valid, and the results obtained using the new sequence were found to be quantitatively the same as results obtained using a standard spin-echo sequence.

Entities:  

Mesh:

Year:  1997        PMID: 9402185     DOI: 10.1002/mrm.1910380603

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Diffusion-weighted MR imaging of the normal human spinal cord in vivo.

Authors:  C A Holder; R Muthupillai; S Mukundan; J D Eastwood; P A Hudgins
Journal:  AJNR Am J Neuroradiol       Date:  2000 Nov-Dec       Impact factor: 3.825

2.  Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence.

Authors:  N Barakat; F B Mohamed; L N Hunter; P Shah; S H Faro; A F Samdani; J Finsterbusch; R Betz; J Gaughan; M J Mulcahey
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

3.  Apparent diffusion coefficients in spinal cord transplants and surrounding white matter correlate with degree of axonal dieback after injury in rats.

Authors:  Eric D Schwartz; Chih-Liang Chin; Jed S Shumsky; Abbas F Jawad; B Kooper Brown; Suzanne Wehrli; Alan Tessler; Marion Murray; David B Hackney
Journal:  AJNR Am J Neuroradiol       Date:  2005-01       Impact factor: 3.825

4.  MR line-scan diffusion imaging of the spinal cord in children.

Authors:  R L Robertson; S E Maier; R V Mulkern; S Vajapayam; C D Robson; P D Barnes
Journal:  AJNR Am J Neuroradiol       Date:  2000-08       Impact factor: 3.825

5.  Multiple-echo diffusion tensor acquisition technique (MEDITATE) on a 3T clinical scanner.

Authors:  Steven H Baete; Gene Cho; Eric E Sigmund
Journal:  NMR Biomed       Date:  2013-07-05       Impact factor: 4.044

6.  Accelerated radial diffusion spectrum imaging using a multi-echo stimulated echo diffusion sequence.

Authors:  Steven H Baete; Fernando E Boada
Journal:  Magn Reson Med       Date:  2017-03-31       Impact factor: 4.668

7.  Full tensor diffusion imaging is not required to assess the white-matter integrity in mouse contusion spinal cord injury.

Authors:  Tsang-Wei Tu; Joong H Kim; Jian Wang; Sheng-Kwei Song
Journal:  J Neurotrauma       Date:  2010-01       Impact factor: 5.269

Review 8.  The current state-of-the-art of spinal cord imaging: methods.

Authors:  P W Stroman; C Wheeler-Kingshott; M Bacon; J M Schwab; R Bosma; J Brooks; D Cadotte; T Carlstedt; O Ciccarelli; J Cohen-Adad; A Curt; N Evangelou; M G Fehlings; M Filippi; B J Kelley; S Kollias; A Mackay; C A Porro; S Smith; S M Strittmatter; P Summers; I Tracey
Journal:  Neuroimage       Date:  2013-05-14       Impact factor: 6.556

9.  Phase-aligned multiple spin-echo averaging: a simple way to improve signal-to-noise ratio of in vivo mouse spinal cord diffusion tensor image.

Authors:  Tsang-Wei Tu; Matthew D Budde; Mingqiang Xie; Ying-Jr Chen; Qing Wang; James D Quirk; Sheng-Kwei Song
Journal:  Magn Reson Imaging       Date:  2014-08-01       Impact factor: 2.546

10.  Single-shot multiecho parallel echo-planar imaging (EPI) for diffusion tensor imaging (DTI) with improved signal-to-noise ratio (SNR) and reduced distortion.

Authors:  Roger Nana; Tiejun Zhao; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.