Literature DB >> 23818212

Three-dimensional magnetization-prepared imaging using a concentric cylinders trajectory.

Kie Tae Kwon1, Holden H Wu, Taehoon Shin, Tolga Cukur, Michael Lustig, Dwight G Nishimura.   

Abstract

PURPOSE: To develop new magnetization-prepared imaging schemes based on a three-dimensional (3D) concentric cylinders trajectory.
METHODS: The 3D concentric cylinders trajectory, which is robust to off-resonance effects and timing delays while requiring fewer excitations than a comparable 3D Cartesian (3DFT) sequence, is used as the readout for magnetization-prepared sequences exploiting its inherently centric-ordered structure. Two applications: (i) T1 -weighted brain imaging with an inversion-recovery-prepared radiofrequency-spoiled gradient-echo (IR-SPGR) sequence, (ii) non-contrast-enhanced (NCE) peripheral angiography with a magnetization-prepared balanced steady-state free precession (bSSFP) sequence are presented to demonstrate the effectiveness of the proposed method. For peripheral angiography, the scan efficiency is further improved by interleaving different preparations at different rates and by carefully designing the sampling geometry for an efficient parallel imaging method.
RESULTS: In vivo brain scans with an IR-SPGR sequence and lower extremity scans with a magnetization-prepared bSSFP sequence for NCE peripheral angiography both demonstrate that the proposed sequences with concentric cylinders effectively capture the transient magnetization-prepared contrast with faster scan times than a corresponding 3DFT sequence. The application of peripheral angiography also shows the feasibility of the proposed interleaving schemes and parallel imaging method.
CONCLUSION: The 3D concentric cylinders trajectory is a robust and efficient readout that is well-suited for magnetization-prepared imaging.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D concentric cylinders; magnetization-prepared imaging; non-Cartesian trajectories

Mesh:

Year:  2013        PMID: 23818212      PMCID: PMC4056679          DOI: 10.1002/mrm.24823

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  T1rho imaging using magnetization-prepared projection encoding (MaPPE).

Authors:  A C Nugent; G A Johnson
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

2.  Reduced aliasing artifacts using variable-density k-space sampling trajectories.

Authors:  C M Tsai; D G Nishimura
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

3.  Optimization of 3-D MP-RAGE sequences for structural brain imaging.

Authors:  R Deichmann; C D Good; O Josephs; J Ashburner; R Turner
Journal:  Neuroimage       Date:  2000-07       Impact factor: 6.556

4.  3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries.

Authors:  V S Deshpande; S M Shea; G Laub; O P Simonetti; J P Finn; D Li
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

5.  Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

Authors:  K Scheffler; O Heid; J Hennig
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

6.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

7.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast.

Authors:  Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu
Journal:  AJR Am J Roentgenol       Date:  2004-08       Impact factor: 3.959

8.  Spectrally selective B1-insensitive T2 magnetization preparation sequence.

Authors:  Reza Nezafat; Ronald Ouwerkerk; Andrew J Derbyshire; Matthias Stuber; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

9.  3D magnetization-prepared imaging using a stack-of-rings trajectory.

Authors:  Holden H Wu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

10.  Magnetization-prepared IDEAL bSSFP: a flow-independent technique for noncontrast-enhanced peripheral angiography.

Authors:  Tolga Cukur; Ann Shimakawa; Huanzhou Yu; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

View more
  6 in total

Review 1.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

2.  Two-dimensional accelerated MP-RAGE imaging with flexible linear reordering.

Authors:  Daniel Brenner; Rüdiger Stirnberg; Eberhard D Pracht; Tony Stöcker
Journal:  MAGMA       Date:  2014-02-08       Impact factor: 2.310

3.  Concentric rings K-space trajectory for hyperpolarized (13)C MR spectroscopic imaging.

Authors:  Wenwen Jiang; Michael Lustig; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2014-12-22       Impact factor: 4.668

4.  Radial fast interrupted steady-state (FISS) magnetic resonance imaging.

Authors:  Ioannis Koktzoglou; Robert R Edelman
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

5.  Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.

Authors:  Kie Tae Kwon; Adam B Kerr; Holden H Wu; Bob S Hu; Jean H Brittain; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

6.  Line scan-based rapid magnetic resonance imaging of repetitive motion.

Authors:  Hankyeol Lee; Jeongtaek Lee; Jang-Yeon Park; Seung-Kyun Lee
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.