PURPOSE: To develop new magnetization-prepared imaging schemes based on a three-dimensional (3D) concentric cylinders trajectory. METHODS: The 3D concentric cylinders trajectory, which is robust to off-resonance effects and timing delays while requiring fewer excitations than a comparable 3D Cartesian (3DFT) sequence, is used as the readout for magnetization-prepared sequences exploiting its inherently centric-ordered structure. Two applications: (i) T1 -weighted brain imaging with an inversion-recovery-prepared radiofrequency-spoiled gradient-echo (IR-SPGR) sequence, (ii) non-contrast-enhanced (NCE) peripheral angiography with a magnetization-prepared balanced steady-state free precession (bSSFP) sequence are presented to demonstrate the effectiveness of the proposed method. For peripheral angiography, the scan efficiency is further improved by interleaving different preparations at different rates and by carefully designing the sampling geometry for an efficient parallel imaging method. RESULTS: In vivo brain scans with an IR-SPGR sequence and lower extremity scans with a magnetization-prepared bSSFP sequence for NCE peripheral angiography both demonstrate that the proposed sequences with concentric cylinders effectively capture the transient magnetization-prepared contrast with faster scan times than a corresponding 3DFT sequence. The application of peripheral angiography also shows the feasibility of the proposed interleaving schemes and parallel imaging method. CONCLUSION: The 3D concentric cylinders trajectory is a robust and efficient readout that is well-suited for magnetization-prepared imaging.
PURPOSE: To develop new magnetization-prepared imaging schemes based on a three-dimensional (3D) concentric cylinders trajectory. METHODS: The 3D concentric cylinders trajectory, which is robust to off-resonance effects and timing delays while requiring fewer excitations than a comparable 3D Cartesian (3DFT) sequence, is used as the readout for magnetization-prepared sequences exploiting its inherently centric-ordered structure. Two applications: (i) T1 -weighted brain imaging with an inversion-recovery-prepared radiofrequency-spoiled gradient-echo (IR-SPGR) sequence, (ii) non-contrast-enhanced (NCE) peripheral angiography with a magnetization-prepared balanced steady-state free precession (bSSFP) sequence are presented to demonstrate the effectiveness of the proposed method. For peripheral angiography, the scan efficiency is further improved by interleaving different preparations at different rates and by carefully designing the sampling geometry for an efficient parallel imaging method. RESULTS: In vivo brain scans with an IR-SPGR sequence and lower extremity scans with a magnetization-prepared bSSFP sequence for NCE peripheral angiography both demonstrate that the proposed sequences with concentric cylinders effectively capture the transient magnetization-prepared contrast with faster scan times than a corresponding 3DFT sequence. The application of peripheral angiography also shows the feasibility of the proposed interleaving schemes and parallel imaging method. CONCLUSION: The 3D concentric cylinders trajectory is a robust and efficient readout that is well-suited for magnetization-prepared imaging.
Authors: Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase Journal: Magn Reson Med Date: 2002-06 Impact factor: 4.668
Authors: Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu Journal: AJR Am J Roentgenol Date: 2004-08 Impact factor: 3.959
Authors: Tolga Cukur; Ann Shimakawa; Huanzhou Yu; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Jean H Brittain Journal: J Magn Reson Imaging Date: 2011-04 Impact factor: 4.813
Authors: Kie Tae Kwon; Adam B Kerr; Holden H Wu; Bob S Hu; Jean H Brittain; Dwight G Nishimura Journal: Magn Reson Med Date: 2014-09-09 Impact factor: 4.668