Reduced aliasing artifacts using variable-density k-space sampling trajectories.

C M Tsai1, D G Nishimura.   

Abstract

A variable-density k-space sampling method is proposed to reduce aliasing artifacts in MR images. Because most of the energy of an image is concentrated around the k-space center, aliasing artifacts will contain mostly low-frequency components if the k-space is uniformly undersampled. On the other hand, because the outer k-space region contains little energy, undersampling that region will not contribute severe aliasing artifacts. Therefore, a variable-density trajectory may sufficiently sample the central k-space region to reduce low-frequency aliasing artifacts and may undersample the outer k-space region to reduce scan time and to increase resolution. In this paper, the variable-density sampling method was implemented for both spiral imaging and two-dimensional Fourier transform (2DFT) imaging. Simulations, phantom images and in vivo cardiac images show that this method can significantly reduce the total energy of aliasing artifacts. In general, this method can be applied to all types of k-space sampling trajectories.

Mesh:

Year:  2000        PMID: 10725889     DOI: 10.1002/(sici)1522-2594(200003)43:3<452::aid-mrm18>3.0.co;2-b

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  53 in total

Review 1.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

2.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

3.  A 2DRF pulse sequence for bolus tracking in hyperpolarized 13C imaging.

Authors:  Shuyu Tang; Wenwen Jiang; Hsin-Yu Chen; Robert Bok; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2014-08-22       Impact factor: 4.668

Review 4.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

5.  Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

Authors:  Refaat E Gabr; Pelin Aksit; Paul A Bottomley; Abou-Bakr M Youssef; Yasser M Kadah
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

6.  Three-dimensional ultrashort echo time cones T (3D UTE-cones-T ) imaging.

Authors:  Ya-Jun Ma; Michael Carl; Hongda Shao; Anthony S Tadros; Eric Y Chang; Jiang Du
Journal:  NMR Biomed       Date:  2017-03-20       Impact factor: 4.044

7.  3D magnetization-prepared imaging using a stack-of-rings trajectory.

Authors:  Holden H Wu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Anisotropic field-of-view shapes for improved PROPELLER imaging.

Authors:  Peder E Z Larson; Michael S Lustig; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2008-09-24       Impact factor: 2.546

9.  Spectrally resolved fully phase-encoded three-dimensional fast spin-echo imaging.

Authors:  Nathan S Artz; Diego Hernando; Valentina Taviani; Alexey Samsonov; Jean H Brittain; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Feasibility of using real-time MRI to measure joint kinematics in 1.5T and open-bore 0.5T systems.

Authors:  Christine E Draper; Juan M Santos; Lampros C Kourtis; Thor F Besier; Michael Fredericson; Gary S Beaupre; Garry E Gold; Scott L Delp
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813