Literature DB >> 11550241

3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries.

V S Deshpande1, S M Shea, G Laub, O P Simonetti, J P Finn, D Li.   

Abstract

The purpose of this work was to develop an ECG-triggered, segmented 3D true-FISP (fast imaging with steady-state precession) technique to improve the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of breath-hold coronary artery imaging. The major task was to optimize an appropriate magnetization preparation scheme to permit saturation of the epicardial fat signal. An alpha/2 preparation pulse was used to speed up the approach to steady-state following a frequency-selective fat-saturation pulse in each heartbeat. The application of dummy cycles was found to reduce the oscillation of the magnetization during data acquisition. The fat saturation and magnetization preparation scheme was validated with simulations and phantom studies. Volunteer studies demonstrated substantially increased SNR (55%) and CNR (178%) for coronary arteries compared to FLASH (fast low-angle shot) with the same imaging time. In conclusion, true-FISP is a promising technique for coronary artery imaging. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11550241     DOI: 10.1002/mrm.1219

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state.

Authors:  Peter Kellman; Michael A Guttman; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

Review 2.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

Review 3.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

4.  Black-blood steady-state free precession (SSFP) coronary wall MRI for cardiac allografts: a feasibility study.

Authors:  Kai Lin; Xiaoming Bi; Ying Liu; Kirsi Taimen; Biao Lu; Debiao Li; James Carr
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

5.  Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow.

Authors:  Peng Hu; Christian T Stoeck; Jouke Smink; Dana C Peters; Long Ngo; Beth Goddu; Kraig V Kissinger; Lois A Goepfert; Jonathan Chan; Thomas H Hauser; Neil M Rofsky; Warren J Manning; Reza Nezafat
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

6.  High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold: parallel imaging with extended cardiac data acquisition.

Authors:  Jaeseok Park; Andrew C Larson; Qiang Zhang; Orlando Simonetti; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

7.  S5FP: spectrally selective suppression with steady state free precession.

Authors:  J A Derbyshire; D A Herzka; E R McVeigh
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

8.  Abdominal fat-water separation with SSFP at 3 Tesla.

Authors:  Janaka P Wansapura
Journal:  Pediatr Radiol       Date:  2006-11-07

9.  Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.

Authors:  Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

10.  Fat-water separation with alternating repetition time balanced SSFP.

Authors:  Tolga Cukur; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.